A novel intensity-based multi-level classification approach for coronary plaque characterization in intravascular ultrasound images
Open Access
- 6 November 2018
- journal article
- conference paper
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (S2) , 1-15
Abstract
Intravascular ultrasound (IVUS) is a commonly used diagnostic imaging method for coronary artery disease. Virtual histology (VH) characterizes the plaque components into fibrous tissue (FT), fibro-fatty tissue (FFT), necrotic core (NC), or dense calcium (DC). However, VH can obtain only a single-frame image in one cardiac cycle, and specific software is needed to obtain the radio frequency data. This study proposed a novel intensity-based multi-level classification model for plaque characterization. The plaque-containing regions between the intima and the media-adventitia were segmented manually for all IVUS frames. A total of 54 features including first order statistics, grey level co-occurrence matrix, Law’s energy measures, extended grey level run length matrix, intensity, and local binary pattern were estimated from the plaque-containing regions. After feature extraction, optimal features were selected using principle component analysis (PCA), and these were utilized as the input for the classification models. Plaque components were classified into FT, FFT, NC, or DC using an intensity-based multi-level classification model consisting of three different nets. Net 1 differentiated low-intensity components into FT/FFT and NC/DC groups. Then, net 2 subsequently divided FT/FFT into FT or FFT, whereas the remainder and high-intensity components were classified into NC or DC via net 3. To improve classification accuracy, each net utilized three different input features obtained by PCA. Classification performance was evaluated in terms of sensitivity, specificity, accuracy, and receiver operating characteristic curve. Quantitative results indicated that the proposed method showed significantly high classification accuracy for all tissue types. The classifiers had classification accuracies of 85.1%, 71.9%, and 77.2%, respectively, and the areas under the curve were 0.845, 0.704, and 0.783. In particular, the proposed method achieved relatively high sensitivity (82.0%) and specificity (87.1%) for differentiating between the FT/FFT and NC/DC groups. These results confirmed the clinical applicability of the proposed approach for IVUS-based tissue characterization.Keywords
This publication has 20 references indexed in Scilit:
- An improved local binary pattern for texture classificationOptik, 2014
- Evaluation of Texture for Classification of Abdominal Aortic Aneurysm After Endovascular RepairJournal of Digital Imaging, 2011
- IVUS-based imaging modalities for tissue characterization: similarities and differencesThe International Journal of Cardiovascular Imaging, 2011
- A New Approach for Improving Coronary Plaque Component Analysis Based on Intravascular Ultrasound ImagesUltrasound in Medicine & Biology, 2010
- A Completed Modeling of Local Binary Pattern Operator for Texture ClassificationIEEE Transactions on Image Processing, 2010
- Intravascular Ultrasound Tissue Characterization with Sub-class Error-Correcting Output CodesJournal of Signal Processing Systems, 2008
- Evaluation of Texture Features in Hepatic Tissue Characterization from Non-enhanced CT Images2007
- Accuracy of In Vivo Coronary Plaque Morphology AssessmentJACC, 2006
- Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data AnalysisCirculation, 2002
- Textural Features for Image ClassificationIEEE Transactions on Systems, Man, and Cybernetics, 1973