Study protocol of a prospective single-arm multicenter clinical study to assess the safety and performance of the aXess hemodialysis graft: The pivotal study
- 10 May 2023
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 25 (4) , 1301-1307
Abstract
Background: Arteriovenous grafts (AVGs) are used for patients deemed unsuitable for the creation of an autogenous arteriovenous fistula (AVF) or unable to await maturation of the AVF before starting hemodialysis. However, AVGs are prone to infection and thrombosis resulting in low long-term patency rates. The novel aXess Hemodialysis Graft consists of porous polymeric biomaterial allowing the infiltration by cells and the growth of neotissue, while the graft itself is gradually absorbed, ultimately resulting in a fully functional natural blood vessel. The Pivotal Study will examine the long-term effectiveness and safety of the aXess Hemodialysis Graft. Methods: The Pivotal Study is a prospective, single-arm, multicenter study that will be conducted in 110 subjects with end-stage renal disease who are not deemed suitable for the creation of an autogenous vascular access. The primary efficacy endpoint will be the primary patency rate at 6 months. The primary safety endpoint will be the freedom from device-related serious adverse events at 6 months. The secondary endpoints will include the procedural success rate, time to first cannulation, patency rates, the rate of access-related interventions to maintain patency, the freedom from device-related serious adverse events and the rate of access site infections. Patients will be followed for 60 months. An exploratory Health Economic and Outcomes Research sub-study will determine potential additional benefits of the aXess graft to patients, health care institutions, and reimbursement programs. Discussion: The Pivotal study will examine the long-term performance and safety of the aXess Hemodialysis Graft and compare the outcome measures with historical data obtained with other graft types and autogenous AVFs. Potential advantages may include superior long-term patency rates and lower infection rates versus currently available AVGs and a shorter time to first cannulation compared to an autologous AVF. As such, the aXess Hemodialysis Graft may fulfill an unmet clinical need in the field of hemodialysis access.Keywords
Funding Information
- Xeltis B.V., Eindhoven, The Netherlands
This publication has 27 references indexed in Scilit:
- Measuring Patient Satisfaction with Vascular Access: Vascular Access Questionnaire Development and Reliability TestingThe Journal of Vascular Access, 2015
- Clinical Analysis of Hemodialysis Vascular Access: Comparision of Autogenous Arterioveonus Fistula & Arteriovenous Prosthetic GraftThe Korean Journal of Thoracic and Cardiovascular Surgery, 2011
- Infection of Hemodialysis Arteriovenous GraftsThe Journal of Vascular Access, 2010
- Prosthetic vascular grafts: Wrong models, wrong questions and no healingBiomaterials, 2007
- Inflow stenosis in arteriovenous fistulas and grafts: A multicenter, prospective studyKidney International, 2005
- Aggressive venous neointimal hyperplasia in a pig model of arteriovenous graft stenosisKidney International, 2002
- Venous neointimal hyperplasia in polytetrafluoroethylene dialysis graftsKidney International, 2001
- Dialysis access grafts: anatomic location of venous stenosis and results of angioplasty.Radiology, 1995
- Bacterial adherence to vascular prosthesesJournal of Vascular Surgery, 1986
- In vitro adherence of bacteria to prosthetic vascular graftsInfection, 1982