Pulmonary embolism in patients with intermediate probability lung scans: diagnosis with Doppler venous US and D-dimer measurement.

Authors:
  • RNR Nour
    R Nour
  • SBS P Butler
    S P Butler
  • DGD W Glenn
    D W Glenn
  • PTP L Travers
    P L Travers
  • GWG Wellings
    G Wellings
  • YKY L Kwan
    Y L Kwan

Abstract
To test the usefulness of lower limb Doppler venous compression ultrasound (US) and serum D-dimer measurements in diagnosis of pulmonary embolism in patients in whom ventilation-perfusion (V-P) scans indicate intermediate probability of pulmonary embolism. V-P scanning, pulmonary angiography, US, and D-dimer measurements were performed in 36 patients without known deep venous thrombosis but with intermediate probability of having a pulmonary embolism. Pulmonary angiography demonstrated pulmonary embolism in 15 (41%) of 36 patients. US demonstrated deep venous thrombosis in only two patients, both with pulmonary embolism. Sensitivity of US was only 13%, but specificity was 100%. Five (14%) of the 36 patients had normal (< 220 micrograms/L) D-dimer levels; none of the five had pulmonary embolism. Sensitivity and specificity of D-dimer values were 100% and 16%, respectively, with a negative predictive value of 100%. Combined D-dimer measurement and US were helpful in correctly diagnosing pulmonary embolism in only seven (20%) of 36 patients. Pulmonary angiography is still required to diagnose pulmonary embolism in the majority of patients.