Abstract
A direct potentiometric method for the determination of the total fluoride concentration in aluminium fluoride and cryolite is proposed. TISAB IV [disodium tartrate–tris(hydroxymethyl)methylamine–hydrochloric acid] buffer is used to complex the aluminium ions and NaOH is added to the standard solutions to keep constant both the ionic strength and the Na+ concentration as well as the pH. No hydroxide ion interference has been detected even though the pH of this solution is 8.57. A sensitivity loss has been recorded as the electrode ages; in spite of this, the potentiometric measurements are free of systematic errors. The response of the Radiometer and Orion fluoride electrodes with the presence of aluminium in the solution has also been studied, and it was noted that addition of aluminium ions to the calibration solutions was necessary when the Orion electrode was used in order to avoid high error levels. The main random error obtained in the whole process is the owing to the reading using the fluoride electrode. A comparison with the Willard–Winter distillation method was also performed.Keywords
This publication has 15 references indexed in Scilit:
- Kinetic determination of EDTA and citrate by the displacement of fluoride from Al3+F− complexes and use of a fluoride ion-selective electrodeTalanta, 1991
- Tiron as a masking reagent for aluminium in the determination of fluoride with an ion-selective electrode: equilibrium studies and applicationThe Analyst, 1988
- Fluoridbestimmung in Pflanzenmaterial mit Hilfe der ionenselektiven ElektrodeAnalytical and Bioanalytical Chemistry, 1982
- An investigation of methods for the analysis of zinc concentrates for their total fluoride contentsTalanta, 1980
- Direct determination of fluoride in aluminium reduction materials by using an ion-selective electrodeTalanta, 1972
- Molar conductivity of sodium fluoride in aqueous solution at 25°C. Applications of Pitts' conductivity equationJournal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases, 1972
- Determination of fluoride in oxides with the fluoride-ion activity electrodeTalanta, 1971
- The use of an ion-selective electrode for routine fluoride analyses on water samplesWater Research, 1969
- An evaluation of some methods for the determination of fluoride in potable waters and other aqueous solutionsThe Analyst, 1968