A gap detection tactility test for sensory deficits associated with carpal tunnel syndrome
Authors:
- 1 December 1995
- journal article
- clinical trial
- Published by Taylor & Francis in Ergonomics
- Vol. 38 (12) , 2588-2601
Abstract
An automated gap detection tactility test was investigated for quantifying sensory deficits associated with carpal tunnel syndrome (CTS). The test, which involved sensing a tiny gap in an otherwise smooth surface by probing with the finger, had functional resemblance to many work-related tactile activities such as detecting scratches or surface defects. Gap detection thresholds were measured using the converging staircase method of limits paradigm. Sixteen normal subjects between 21 and 66 years of age were tested for studying important factors affecting gap detection thresholds. Actively probing with the index finger had a threshold almost an order of magnitude more sensitive (mean = 0·19mm, SD = 0·llmm) than passive touch (mean =1·63mm. SD = 0·62mm), which was similar to two-point discrimination. Average thresholds decreased by 24% as contact force increased from 25 to 75 g. Performance in this tactility test quickly stabilized and showed little learning effects over the period of the test, as evidenced by the lack of significant differences between six replicates. The results were highly repeatable. No significant threshold differences were observed between test and retest trials on different days, or between dominant and non-dominant hands. A contact force of 50 g was recommended as optimal for this test since it required moderate force but resulted in a smaller threshold compared with 25 or 75 g. A companion study was conducted using eight normal subjects and ten subjects diagnosed as having CTS. Average gap detection threshold, when finger probing was allowed, was 0·20 mm (SD = 0·11 min) for the normal subjects and increased two-fold to 0·40 mm (SD = 0·19 mm) for the CTS subjects. Average gap detection threshold, when the finger probing was not allowed, was 1·71 mm (SD = 0·53mm) for the normal subjects and increased by 48% to 2·53 mm (SD = 0·87 mm) for the CTS subjects. The results suggest that people suffering from CTS may experience similar functional deficits in daily living and work activities. The small inter-subject variability makes this test a candidate for having utility as a monitoring test for loss of cutaneous tactile sensitivity.Keywords
This publication has 20 references indexed in Scilit:
- A new automated tactility test instrument for evaluating hand sensory functionIEEE Transactions on Rehabilitation Engineering, 1993
- Testing Sensibility, Including Touch-Pressure, Two-point Discrimination, Point Localization, and VibrationJournal of Hand Therapy, 1993
- Ridge Detection Tactility Deficits Associated with Carpal Tunnel SyndromeJournal of Occupational and Environmental Medicine, 1991
- The force/time relationship of clinically used sensory testing instrumentsJournal of Hand Therapy, 1988
- Tactile Detection Thresholds for a Single Asperity on an Otherwise Smooth SurfaceSomatosensory Research, 1983
- The role of vibration in the tactual perception of roughnessPerception & Psychophysics, 1982
- Tactile roughness of grooved surfaces: The touching process and effects of macro- and microsurface structurePerception & Psychophysics, 1974
- Fingertip force, surface geometry, and the perception of roughness by active touchPerception & Psychophysics, 1972
- Median Nerve Neuropathy at the WristClinical Orthopaedics and Related Research, 1972
- Aetiology, Diagnosis, and Treatment of Paraesthesiae in the HandsBMJ, 1960