Accelerating Corrosion of Pure Magnesium Co-implanted with Titanium in Vivo
Open Access
- 7 February 2017
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep41924
Abstract
Magnesium is a type of reactive metal, and is susceptible to galvanic corrosion. In the present study, the impact of coexistence of Ti on the corrosion behavior of high purity Mg (HP Mg) was investigated both in vitro and in vivo. Increased corrosion rate of HP Mg was demonstrated when Mg and Ti discs were not in contact. The in vivo experiments further confirmed accelerating corrosion of HP Mg screws when they were co-implanted with Ti screws into Sprague-Dawley rats’ femur, spacing 5 and 10 mm. Micro CT scan and 3D reconstruction revealed severe corrosion morphology of HP Mg screws. The calculated volume loss was much higher for the HP Mg screw co-implanted with Ti screw as compared to that co-implanted with another Mg screw. Consequently, less new bone tissue ingrowth and lower pullout force were found in the former group. It is hypothesized that the abundant blood vessels on the periosteum act as wires to connect the Mg and Ti screws and form a galvanic-like cell, accelerating the corrosion of Mg. Therefore, a certain distance is critical to maintain the mechanical and biological property of Mg when it is co-implanted with Ti.Keywords
This publication has 43 references indexed in Scilit:
- Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot studyBioMedical Engineering OnLine, 2013
- Electron Transfer in Peptides: The Influence of Charged Amino AcidsAngewandte Chemie International Edition, 2011
- Effects of magnesium alloys extracts on adult human bone marrow-derived stromal cell viability and osteogenic differentiationBiomedical Materials, 2010
- Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogramPhysiological Measurement, 2009
- In vitro corrosion and biocompatibility of binary magnesium alloysBiomaterials, 2009
- Corrosion behavior of titanium in the presence of calcium phosphate and serum proteinsBiomaterials, 2005
- Effect of synovial fluid, phosphate‐buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implantsJournal of Biomedical Materials Research Part A, 2005
- Study of corrosion between a titanium implant and dental alloysJournal of Dentistry, 1994
- Corrosion current and pH rise around titanium coupled to dental alloysEuropean Journal of Oral Sciences, 1988
- In vitro electrochemical corrosion study of coupled surgical implant materialsJournal of Biomedical Materials Research, 1983