Comparing Immobilization, Recovery, and Stress Indicators Associated with Electric Fish Handling Gloves and a Portable Electrosedation System
- 25 March 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Transactions of the American Fisheries Society
- Vol. 147 (2) , 390-399
Abstract
Fish sedation facilitates safer handling of fish during scientific research or fisheries assessment practices, thus limiting risk of injury to fish and reducing stress responses. In recent years, there has been growing interest in using electricity to sedate fish; two methods include (1) lower‐voltage, non‐pulsed‐DC fish handling gloves (FHGs) that tend to only sedate fish while the gloves are touching the animal; and (2) a comparatively high‐voltage, pulsed‐DC Portable Electrosedation System (PES) that leads to galvanonarcosis. This study compared the physiological consequences of exposure to FHGs and PES in teleost fish. Bluegills Lepomis macrochirus and Largemouth Bass Micropterus salmoides were exposed to FHGs, PES, or a handling control for a 3‐min simulated surgery. Blood was then sampled at 0.5 and 4.5 h postexposure and was analyzed for blood glucose, blood lactate, and plasma cortisol concentrations. Opercular rates were monitored during surgery, at 2 min postsurgery, and 0.5 h postsurgery. At 24 h postsurgery, time to exhaustion (via a standardized swimming chase protocol) was assessed. Fish exposed to FHGs tended to exhibit lower opercular rates than fish that were sedated with the PES during simulated surgery. Cortisol levels of Largemouth Bass treated with FHGs were higher than those of fish sedated with the PES. Glucose levels recorded for Bluegills at 4.5 h postsurgery were higher with FHGs than with the PES. In both species, lactate was lower for fish treated with FHGs than for those treated with the PES. At 24 h posttreatment, Bluegills sedated with FHGs exhibited a longer time to exhaustion than those subjected to the PES, whereas Largemouth Bass sedated with the PES exhibited a longer time to exhaustion than those sedated with FHGs. Physiological responses to treatments were inconsistent between species. Further investigation to determine the optimal electrosedation method is required.Keywords
This publication has 36 references indexed in Scilit:
- Resilience of Pink Salmon and Chum Salmon to Simulated Fisheries Capture Stress Incurred upon Arrival at Spawning GroundsTransactions of the American Fisheries Society, 2013
- Issues Regarding the Use of Sedatives in Fisheries and the Need for Immediate‐Release OptionsTransactions of the American Fisheries Society, 2012
- Tricaine methane-sulfonate (MS-222) application in fish anaesthesiaJournal of Applied Ichthyology, 2012
- Electrofishing Practices Have Limited Effects on Largemouth Bass Feeding BehaviorNorth American Journal of Fisheries Management, 2010
- The influence of environmental temperature and oxygen concentration on the recovery of largemouth bass from exercise: implications for live–release angling tournamentsJournal of Fish Biology, 2006
- Physiological Significance of the Weigh-In during Live-Release Angling Tournaments for Largemouth BassTransactions of the American Fisheries Society, 2004
- Effects of anaesthesia with MS-222, clove oil and CO2 on feed intake and plasma cortisol in steelhead trout (Oncorhynchus mykiss)Aquaculture, 2003
- Are Better Anesthetics Needed in Fisheries?Fisheries, 1985
- Use of electroanaesthesia with freshwater teleosts: some physiological consequences in the rainbow trout, Salmo gairdneri RichardsonJournal of Fish Biology, 1976
- Influence of sampling methods and anaesthetization on various haematological parameters of several teleostsAquaculture, 1975