Low-Frequency Magnetic Induction Tomography for Superparamagnetic Iron Oxide Nanoparticle-Based Stroke Imaging
- 9 June 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 4505214
Abstract
Stroke is a leading cause of mortality and disability worldwide, with rapid diagnosis critical for effective intervention. Conventional imaging modalities such as CT and MRI are limited by their size, cost, and unsuitability for bedside or prehospital emergency use. This study presents a novel Superparamagnetic Iron Oxide Nanoparticles (SPIOs) based Magnetic Induction Tomography (SPIO-MIT) for non-invasive stroke-tracing imaging. Operating at an ultra-low excitation frequency of 3 kHz and a magnetic field strength below 1 mT, the system effectively suppresses background interference from biological tissues while enhancing sensitivity to SPIOs distribution. System performance was validated through phantom experiments featuring varied SPIOs positions, geometries, and concentration gradients, confirming accurate imaging of SPIOs with negligible response to low-conductivity substances. Complementary in vitro experiments embedding SPIO-blood mixtures in biological tissues demonstrated minimal background interference. In vivo experiments on a rabbit intracerebral hemorrhage model further confirmed precise localization of SPIOs injected into the brain, with detection sensitivity down to 1.2 mg of iron and an imaging diameter of 60 mm. In summary, the developed SPIO-MIT system enables sensitive, non-invasive spatial mapping of SPIOs. By combining the high sensitivity of magnetic particle imaging with the operational simplicity and biological safety of magnetic induction tomography, SPIO-MIT represents a promising technique for portable, bedside, and prehospital stroke diagnostics.Keywords
Funding Information
- Foundation of technology innovation and application development project of Chongqing Municipality (CSTB2025TIAD-KPX0008)
- Natural Science Foundation of Beijing Municipality (CSTB2024NSCQ-MSX0762)
- National Natural Science Foundation of China (52477236)
This publication has 32 references indexed in Scilit:
- Simulation study of abdominal hemorrhage based on magnetic induction tomographyReview of Scientific Instruments, 2024
- System characterization of a human-sized 3D real-time magnetic particle imaging scanner for cerebral applicationsCommunications Engineering, 2024
- Magnetic particle imaging for assessment of cerebral perfusion and ischemiaWIREs Nanomedicine and Nanobiotechnology, 2021
- Monitoring Intracranial Cerebral Hemorrhage Using Multicontrast Real-Time Magnetic Particle ImagingACS Nano, 2020
- Global, regional, and national burden of stroke, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016The Lancet Neurology, 2019
- Magnetic Particle Imaging for Real-Time Perfusion Imaging in Acute StrokeACS Nano, 2017
- Magnetic Particle Imaging2012
- Tomographic imaging using the nonlinear response of magnetic particlesNature, 2005
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The rabbit diencephalon in stereotaxic coordinatesJournal of Comparative Neurology, 1954