Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
Authors:
- Héctor Pereiro-BucetaHéctor Pereiro-Buceta
- César Calvo-LoboCésar Calvo-Lobo
- Ricardo Becerro-De-Bengoa-VallejoRBRicardo Becerro-De-Bengoa-Vallejo
- Marta Elena Losa-IglesiasMLMarta Elena Losa-Iglesias
- Carlos Romero-MoralesCarlos Romero-Morales
- Daniel López-LópezDaniel López-López
- Eva-María Martínez-JiménezEMEva-María Martínez-Jiménez
Open Access
- 25 June 2021
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 139 (5) , 424-434
Abstract
Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. To determine the intra and intersession repeatability and reliability of dynamic parameters of the Podoprint pressure platform under simulated LLD conditions. Observational cross-sectional study at a public university. Thirty-seven healthy volunteers participated in this study. LLD was simulated using ethyl vinyl acetate plantar lifts with heights of 5 mm, 10 mm, 15 mm and 20 mm located under the right shoe of each volunteer. The procedure was performed to capture the dynamic parameters of each participant under five different simulated LLD conditions. Stance time, mean pressure and peak pressure measurements were registered in three trials for each foot and each LLD level. Data were collected during two separate testing sessions, in order to establish intrasession and intersession reliability. The intraclass correlation coefficients (ICCs) for intrasession reliability ranged from 0.775 to 0.983 in the first session and from 0.860 to 0.985 in the second session. The ICCs for intersession reliability ranged from 0.909 to 0.990. Bland-Altman plots showed absence of systematic measurement errors. The results from this study indicate that the Podoprint platform is a reliable system for assessing dynamic parameters under simulated LLD conditions. Future studies should evaluate plantar pressures under LLD conditions, in association with exercise, biomechanics and musculoskeletal disorders.Keywords
This publication has 43 references indexed in Scilit:
- Determination of the amount of leg length inequality that alters spinal posture in healthy subjects using rasterstereographyEuropean Spine Journal, 2013
- A Review of Symptomatic Leg Length Inequality following Total Hip ArthroplastyHIP International, 2013
- Using Cadence to Study Free-Living Ambulatory BehaviourSports Medicine, 2012
- Nordic Walking Practice Might Improve Plantar Pressure DistributionResearch Quarterly for Exercise and Sport, 2011
- The effect of simulating leg length inequality on spinal posture and pelvic position: a dynamic rasterstereographic analysisEuropean Spine Journal, 2011
- Association of flat feet with knee pain and cartilage damage in older adultsArthritis Care & Research, 2011
- Dynamic Principles of Gait and Their Clinical ImplicationsPhysical Therapy, 2010
- Are differences in leg length predictive of lateral patello‐femoral pain?Physiotherapy Research International, 2006
- Biomechanical implications of mild leg length inequality.British Journal of Sports Medicine, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986