Abstract
An analysis of the levelness of three residential floor slabs constructed on-grade in the Phoenix, Arizona, metropolitan area is presented. The slabs were built using typical methods by a trade subcontractor for a large production builder in different subdivisions. Measurements of the elevation of the floor slabs were made at 0.3 m (1 ft) spacing across the entire surface of all three slabs within the first week after concrete placement. The resulting elevation data were then used as input in several different analytical techniques, including the maximum elevation difference, maximum slope, FL local, and FL. Special consideration was given to the sample size effects and the repeatability of the results for different samples. All of these methods were found to exhibit dependency on sample size or location, leading to undesirable characteristics. An analysis based on the three-standard-deviation range of the elevation measured from a sample of about 80 points widely spread across the surface of the slab is ...Keywords
This publication has 5 references indexed in Scilit:
- State of Practice of Residential Floor Slab FlatnessJournal of Performance of Constructed Facilities, 2001
- Damage and Distortion Criteria for Residential Slab-on-Grade StructuresJournal of Performance of Constructed Facilities, 1999
- Ground-Movement-Related Building DamageJournal of Geotechnical Engineering, 1996
- Differential Movement of Slab‐on‐Grade StructuresJournal of Performance of Constructed Facilities, 1990
- THE ALLOWABLE SETTLEMENTS OF BUILDINGS.Proceedings of the Institution of Civil Engineers, 1956