Study on parameters influencing analytical performance of laser-induced breakdown spectroscopy
Authors:
- 19 October 2012
- journal article
- research article
- Published by China Engineering Science Press Co. Ltd. in Frontiers of Physics
- Vol. 7 (6) , 714-720
Abstract
Lens-to-sample distances, delay time, atmospheric condition, laser pulse energy, etc. had obvious effects on the analytical performance of laser-induced breakdown spectroscopy. In this paper, these parameters are investigated in greater detail and we will explain how they have influences on the analytical performance. The results show that the focal plane under the sample surface can improve precision and detection limit, and the delay time should be decided according to sensitivity and accuracy. Spectral line intensity is stronger in argon than helium, nitrogen and air gas environment. Pulse energy should exceed energy threshold (about 50 mJ) which can generate plasma, and the energy should not exceed about 300 mJ to avoid plasma shielding. Under optimum parameters, concentration relative standard deviation of C, Si, Mn, P, S, Ni, and Cr for low-alloyed steel (sample number 11278) which were measured 11 times is 2.37%, 2.18%, 2.23%, 7.8%, 9.34%, 1.92%, and 2.13%, respectively. And the detection limit of C, Si, Mn, P, S, Ni, and Cr for pure steel is 0.0045%, 0.0072%, 0.0069%, 0.0027%, 0.0024%, 0.0047%, and 0.0024%, respectively.Keywords
This publication has 21 references indexed in Scilit:
- Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the artSpectrochimica Acta Part B: Atomic Spectroscopy, 2010
- High-speed scanning laser-induced breakdown spectroscopy at 1000 Hz with single pulse evaluation for the detection of inclusions in steelJournal of Laser Applications, 2005
- Inclusion mapping and estimation of inclusion contents in ferrous materials by fast scanning laser-induced optical emission spectrometryJournal of Analytical Atomic Spectrometry, 2005
- Characterization of a laser-induced plasma by spatially resolved spectroscopy of neutral atom and ion emissions.Spectrochimica Acta Part B: Atomic Spectroscopy, 2004
- A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samplesSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Laser-induced breakdown spectrometry — applications for production control and quality assurance in the steel industrySpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Application of vacuum ultraviolet laser-induced breakdown spectrometry for steel analysis — comparison with spark-optical emission spectrometry figures of meritSpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- New Procedure for Quantitative Elemental Analysis by Laser-Induced Plasma SpectroscopyApplied Spectroscopy, 1999
- Spectroscopic Imaging of Laser-Induced PlasmaAnalytical Chemistry, 1996
- Laser-induced breakdown spectroscopy of steel samples using multiple Q-switch Nd:YAG laser pulsesJournal of Physics D: Applied Physics, 1995