Craniocervical Fixation With Occipital Condyle Screws
Authors:
- Juan S. UribeJUJuan S. Uribe
- Edwin RamosEREdwin Ramos
- A Samy YoussefAYA Samy Youssef
- Nick LevineNLNick Levine
- Alexander W. L. TurnerATAlexander W. L. Turner
- Wesley M. JohnsonWJWesley M. Johnson
- Fernando L. ValeFVFernando L. Vale
- 1 April 2010
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 35 (9) , 931-938
Abstract
A human cadaveric biomechanical study comparing craniocervical fixation techniques. To quantitatively compare the biomechanical stability of a new technique for occipitocervical fixation using the occipital condyles with an established method for craniocervical spine fusion. Stabilization of the occipitocervical junction remains a challenge. The occiput does not easily accommodate instrumentation because of access and spatial constraints. In fact, the area available for the implant fixation is limited and can be restricted further when a suboccipital craniectomy has been performed, posing a challenge to current fixation techniques. Occipital screws are also associated with the potential for intracranial complications. Six fresh frozen cadaveric specimens occiput-C4 were tested intact, after destabilization and after fixation as follows: (1) occipital plate with C1 lateral mass screws and C2 pars screws and (2) occipital condyle screws with C1 lateral mass screws and C2 pars screws. Specimens were loaded in a custom spine testing apparatus and subjected to the following tests, all performed under 50-N unconstrained axial preload: flexion, extension, lateral bending, and axial rotation at 1.5 Nm. The constructs were statistically compared with a one-way analysis of variance and compared with the intact condition. Motions were reduced by approximately 80% compared with the intact condition for both configurations under all motions. There were no statistically significant differences in the range of motion (ROM) between the 2 instrumentation conditions. The mean values indicated decreased ROM with the novel occipital condyle screw construct in comparison with the standard occipital plate and rod system. Craniocervical stabilization using occipital condyle screws as the sole cephalad fixation point is biomechanically equivalent with regard to the modes tested (ROM and stiffness) to the standard occipital plate construct.Keywords
This publication has 33 references indexed in Scilit:
- Occipitocervical fusion with rigid internal fixation: long-term follow-up data in 69 patientsJournal of Neurosurgery: Spine, 2007
- Anatomical, biomechanical, and practical considerations in posterior occipitocervical instrumentationThe Spine Journal, 2006
- Indications for surgery and stabilization techniques of the occipito-cervical junctionInjury, 2005
- Posterior occipitocervical fusion in rheumatoid arthritis and other instabilitiesJournal of Orthopaedic Science, 2000
- Occipital Screw Pullout StrengthSpine, 1999
- Craniovertebral junction anomalies: Diagnosis and managementSeminars in Pediatric Neurology, 1997
- Plate and screw fixation for atlanto-axial subluxationActa Neurochirurgica, 1994
- Posterior Occipitocervical FusionSpine, 1991
- Moment-rotation relationships of the ligamentous occipito-atlanto-axial complexJournal of Biomechanics, 1988
- OCCIPITO-CERVICAL FUSIONThe Journal of Bone and Joint Surgery. British volume, 1967