Performance evaluation of human cytokines profiles obtained by various multiplexed-based technologies underlines a need for standardization
Authors:
- Anne Marie DupuyADAnne Marie Dupuy
- Nils KusterNKNils Kuster
- Gérard LizardGLGérard Lizard
- Kévin RagotKRKévin Ragot
- Sylvain LehmannSLSylvain Lehmann
- Benoît GallixBGBenoît Gallix
- Jean Paul CristolJCJean Paul Cristol
- 1 January 2013
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (7) , 1385-1393
Abstract
Multiplexed methods permit simultaneous quantification of multiple cytokines. As several manufacturers offer reagents to quantify the same cytokines on a single instrument, comparison of the distribution should be made to determine whether these data are comparable from one assay to another. We performed the quantification of cytokines in serum samples with three commercially available assays: Cytometric Bead Array (CBA), Protein Biochip Array Technology (PBAT), and Luminex Technology analysis. Using detection limit and reference range of the three commercial multiplex technologies, we evaluated: 1) the overall distribution of cytokines; and 2) the clinical impact. The three cytokines, IL-1β, IL-1α and IL-4, cannot be measured by these methods because of the high number of non-detected data (>50%). By contrast, four cytokines as IL-8, VEGF, MCP-1 and EGF exhibited a low percentage of non-detected data whatever method was used. The comparison of the percentage of samples with values higher than the respective reference range of each method reported an absence of clinical concordance (Cohen's κ-test <0.40). Our results highlight the lack of transferability between the three commercially available multiplex methods evaluated (CBA, PBAT and Luminex Technology). Analytical performances are adequate for longitudinal studies using a same methodology but caution should be used for comparisons between results obtained with different methods underlying a need for standardization.Keywords
This publication has 11 references indexed in Scilit:
- Fine-Tuning of the Prediction of Mortality in Hemodialysis Patients by Use of Cytokine Proteomic DeterminationClinical Journal of the American Society of Nephrology, 2008
- Biochip Array‐based Analysis of Plasma Cytokines in HIV Patients with Immunological and Virological DiscordanceScandinavian Journal of Immunology, 2007
- Cytokine profiles as markers of disease severity in sepsis: a multiplex analysisCritical Care, 2007
- Fabricating data: How substituting values for nondetects can ruin results, and what can be done about itChemosphere, 2006
- Multiplex bead array assays: Performance evaluation and comparison of sensitivity to ELISA☆Methods, 2006
- Solid-phase and bead-based cytokine immunoassay: A comparisonMethods, 2006
- Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: Determinations of a panel of nine cytokines in clinical sample culture supernatantsJournal of Reproductive Immunology, 2005
- Development of a High-Throughput Automated Analyzer Using Biochip Array TechnologyClinical Chemistry, 2005
- Multiplexed Analysis of Biomarkers Related to Obesity and the Metabolic Syndrome in Human Plasma, Using the Luminex-100 SystemClinical Chemistry, 2005
- Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturersCytometry Part B: Clinical Cytometry, 2004