Determining Optimal Waste Volume From an Intravenous Catheter
Authors:
- 1 March 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Infusion Nursing
- Vol. 36 (2) , 92-96
Abstract
Waste is blood drawn from an intravenous (IV) catheter to remove saline or heparin before obtaining a blood sample. This study examines the minimum waste volume resulting in an undiluted sample. A repeated-measures design was used. Investigators placed an IV catheter in 60 healthy adults and obtained samples at baseline and following waste volumes ranging from 0.5 to 3 mL. A random effects mixed model was used to determine the stabilizing point, which was 1 mL of waste. Knowing that only 1 mL of waste is needed will prevent clinicians from obtaining extra waste and discarding blood needlessly.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of Laboratory Values Obtained by Phlebotomy versus Saline Lock DevicesAcademic Emergency Medicine, 2007
- Use of peripheral venous access devices for obtaining blood samples for measurement of activated partial thromboplastin times.2006
- Blood sample collection from a peripheral catheter system compared with phlebotomy.2002
- Comparison of laboratory values obtained by means of routine venipuncture versus peripheral intravenous catheter after a normal saline solution bolusAnnals of Emergency Medicine, 2001
- Accuracy of drawing blood through infusing intravenous linesHeart & Lung, 2001
- The effect of draw‐up volume on the accuracy of electrolyte measurements from neonatal arterial linesJournal of Paediatrics and Child Health, 2000
- Reliability of an intravenous intermittent access port (saline lock) for obtaining blood samples for coagulation studiesAmerican Journal of Critical Care, 1999
- Obtaining blood samples for coagulation studies from a normal saline lockAmerican Journal of Critical Care, 1999
- The reliability of blood sampling from peripheral intravenous infusion lines. Complete blood cell counts, electrolyte panels, and survey panels.1998
- Intravenous catheter aspiration for obtaining basic analytes during intravenous infusionAnnals of Emergency Medicine, 1990