A comparison of self-ligating and conventional orthodontic bracket systems.
Authors:
- S P JonesSJS P Jones
- E H DaviesEDE H Davies
- 1 November 1997
- journal article
- research article
- Published by Taylor & Francis in British Journal of Orthodontics
- Vol. 24 (4) , 309-317
Abstract
This ex-vivo study compared the static frictional resistance of three self-ligating brackets with a conventional steel-ligated Ultratrimm bracket. The effects of archwire size (0.020, 0.019 x 0.025 and 0.021 x 0.025-inch), bracket/archwire angulation (0, 5 and 10 degrees) and the presence of unstimulated human saliva were investigated. The study demonstrated that both increases in wire size and bracket/archwire angulation resulted in increased static frictional resistance for all bracket types tested, with the presence of saliva having an inconsistent effect. Mobil-Lock Variable-Slot had the least friction for all wires for 0 degree angulation. However, with the introduction of angulation, the values were comparable to those of the other brackets. Activa brackets had the second lowest frictional resistance, although high values were found with 0.019 x 0.025-inch wires. SPEED brackets demonstrated low forces with round wires, although with rectangular wires or in the presence of angulation, friction was greatly increased. Ultratrimm brackets produced large individual variation, confirming the difficulty in standardizing ligation force, although under certain conditions, significantly larger frictional forces were observed. In conclusion, self-ligating brackets showed reduced frictional resistance in comparison to steel ligated brackets only under certain conditions.Keywords
This publication has 25 references indexed in Scilit:
- The SPEED appliance: A 14-year update on this unique self-ligating orthodontic mechanismAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1994
- (Up)Righting misconceptions concerning the SPEED bracket systemAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1992
- A comparative study of frictional forces between orthodontic brackets and arch wiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1991
- Der Kraftverlust durch Friktion bei der bogengeführten ZahnbewegungJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 1990
- The influence of the SPEED bracket's self-ligating design on force levels in tooth movement: A comparative in vitro studyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1990
- Frictional forces between bracket and arch wireAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1989
- Frictional changes in force values caused by saliva substitutionAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1987
- An Evaluation of Different Methods of Canine RetractionBritish Journal of Orthodontics, 1977
- Optimizing anterior and canine retractionAmerican Journal of Orthodontics, 1976
- Evaluation of friction forces in the 0·022 × 0·028 edgewise bracket in vitroJournal of Biomechanics, 1970