Conductor geometry and capacitor quality for performance optimization of low‐frequency birdcage coils
- 26 January 2004
- journal article
- research article
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 20B (1) , 9-16
Abstract
Birdcage coils are used widely in nuclear magnetic resonance (NMR) applications for their ability to operate in transmit/receive mode with high signal‐to‐noise ratio (SNR) and wide field homogeneity. When used at low frequencies, a number of drawbacks arise that drastically reduce their overall performances. In this article we show how the choice of the conductors cross‐geometry and capacitor quality affects the coil overall performance. Several birdcage coils, tuned at 7.66 MHz, were designed and built, using conductors with different shapes and capacitors with different quality factors. Realized coils were tested and characterized by laboratory workbench in order to extract several quality indices. In addition, experiments were done in a real magnetic resonance (MR) scanner to evaluate the field homogeneity. We show that an optimized choice of conductor shape and capacitors allows us to obtain high‐quality birdcage coils tuned at frequencies in the megahertz range. Our results are applicable in several situations as MR imaging (MRI) in low‐field scanners, imaging of nuclear species at intermediate fields, Overhauser systems, and prepolarized NMR. © 2004 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 20B: 9–16, 2004.Keywords
This publication has 20 references indexed in Scilit:
- A Birdcage Coil Tuned by RF Shielding for Application at 9.4 TJournal of Magnetic Resonance, 1998
- Transverse low‐field RF coils in MRIMagnetic Resonance in Medicine, 1996
- Optimized Small-Bore, High-Pass Resonator DesignsJournal of Magnetic Resonance, Series B, 1995
- An efficient birdcage resonator at 2.5 MHz using a novel multilayer self-capacitance construction techniqueMagnetic Resonance Materials in Physics, Biology and Medicine, 1995
- Implementation of a modified birdcage resonator for 19F/1H MRI at low fields (0.14 T)Medical Physics, 1994
- Quick measurement of NMR-coil sensitivity with a dual-loop probeReview of Scientific Instruments, 1993
- An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 TJournal of Magnetic Resonance (1969), 1985
- Quadrature detection coils—A further √2 improvement in sensitivityJournal of Magnetic Resonance (1969), 1983
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976