Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose
Open Access
- 20 March 2010
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 20 (8) , 1917-1925
Abstract
Objective To prospectively investigate the influence of contrast material concentration on enhancement in cardiac CT by using a biphasic single-injection protocol. Methods Sixty-four-row multidetector cardiac CT angiography was performed in 159 patients randomised to a moderate or high contrast medium concentration. Contrast material injection included a first phase for enhancement of the coronary arteries and a second phase, at half the iodine flux, targeted at enhancement of the right ventricle. Contrast medium injection was followed by a saline flush. For both concentrations, injection duration (and thus total iodine dose) was adapted to the duration of the CT data acquisition and iodine flux was adjusted to patient weight. Attenuation was measured at various levels in the heart and vessels and the two concentrations compared, overall and per weight group. Results Enhancement of the aorta and left ventricle was significantly greater with the moderate than with the high concentration contrast medium. This remained true for the two higher weight groups. No difference was found in the lowest weight group or in the right ventricle and pulmonary outflow tract. Conclusion With a biphasic injection protocol, enhancement of the aorta and left ventricle was weaker with the higher concentration of contrast material.Keywords
This publication has 25 references indexed in Scilit:
- Contrast Enhancement in Chest Multidetector Computed Tomography: Intraindividual Comparison of 300 mg/ml versus 400 mg/ml Iodinated Contrast MediumAcademic Radiology, 2009
- Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCTAmerican Journal of Roentgenology, 2008
- Contrast Bolus Optimization for Cardiac 16-Slice Computed TomographyInvestigative Radiology, 2006
- High Iodine Concentration Contrast Material for Noninvasive Multislice Computed Tomography Coronary AngiographyInvestigative Radiology, 2006
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJACC, 2005
- Jodeinbringungsgeschwindigkeit verschieden konzentrierter Röntgenkontrastmittel bei schneller intravenöser InjektionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Refresherkurs Spiral-CT bei Polytrauma – Effektives Untersuchungsprotokoll mit 16-Schicht-Spiral-CT: „Rush-CT“RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Optimal Contrast Application for Cardiac 4-Detector-Row Computed TomographyInvestigative Radiology, 2003
- Use of high concentration contrast media: principles and rationale—vascular districtEuropean Journal of Radiology, 2003