A Structurally Enhanced Neck Exoskeleton to Assist with Head-Neck Motion
Authors:
- 19 April 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Abstract
This paper presents the design of a neck exoskeleton to assist with head-neck motion for patients with amyotrophic lateral sclerosis (ALS). Motor neuron degeneration caused by ALS can lead to neck muscle weakness, resulting in head drop (chin-on-chest posture). Current treatment using static neck collars is inadequate because these collars completely immobilize the head. A powered neck exoskeleton (Columbia exoskeleton) was previously developed to assist with head-neck movements but its structural limitations hindered its usability for patients with severe head drop. In this paper, we introduce the Utah neck exoskeleton which improved the structural stability of the previous Columbia design by (1) optimizing the transmission efficiency and range of motion, and (2) using more precise mechanical components. We quantified the structural stability of the Utah neck exoskeleton and demonstrated its usability with a healthy volunteer. The results show that the Utah neck exoskeleton has a suitable structure to potentially assist with head-neck movements for patients with severe ALS head drop.Keywords
This publication has 17 references indexed in Scilit:
- An Active Neck Brace Controlled by a Joystick to Assist Head MotionIEEE Robotics and Automation Letters, 2017
- Kinematic Design of a Dynamic Brace for Measurement of Head/Neck MotionIEEE Robotics and Automation Letters, 2017
- A 6-DOF exoskeleton for head and neck motion assist with parallel manipulator and sEMG based control2016
- Evaluating a novel cervical orthosis, the Sheffield Support Snood, in patients with amyotrophic lateral sclerosis/motor neuron disease with neck weaknessAmyotrophic Lateral Sclerosis and Frontotemporal Degeneration, 2016
- Amyotrophic lateral sclerosisThe Lancet, 2011
- Utility of trapezius EMG for diagnosis of amyotrophic lateral sclerosisMuscle & Nerve, 2008
- Jacobian, Manipulability, Condition Number, and Accuracy of Parallel RobotsJournal of Mechanical Design, 2005
- The 3-RRS Wrist: A New, Simple and Non-Overconstrained Spherical Parallel ManipulatorJournal of Mechanical Design, 2004
- Design and workspace analysis of a 6–6 cable-suspended parallel robotMechanism and Machine Theory, 2004
- Human Head Tolerance to Sagittal Impact Reliable Estimation Deduced from Experimental Head Injury Using Subhuman Primates and Human Cadaver SkullsSAE International Journal of Advances and Current Practices in Mobility, 1980