Diabetes is a chronic disease affecting 10% of the population globally, and can lead to serious damage in the heart, kidneys, eyes, blood vessels or nerves. Commercial artificial closed-loop feedback systems can significantly improve diabetes management and save lives. However, they are large and expensive for users. Here, we demonstrate for the first time a wearable, minimally-invasive, fully electrochemically-controlled feedback minisystem for diabetes management. Both the working principles of the sensor and pump in the feedback system are based on electrochemical reactions. The smart minisystem was constructed based on integrating the thermoplastic polyurethane hollow microneedles with an electrochemical biosensing device on its outer layer and an electrochemical micropump facing the inner layer of the microneedles. The sensing device was constructed based on sputtering thin metal films through a shadow mask and electroplating Prussian blue on the surface of the microneedles, followed by the immobilization of glucose oxidase on the working electrode. The electrochemical micropump was constructed by sputtering the interdigital electrodes, followed by sealing with a thin elastic film, which was further integrated with the inner channels of the microneedles. Both the sensor and the pump were electrically powered. Via being controlled by a printed circuit board, the biosensing device monitored the levels of interstitial glucose continuously to drive the electrochemical pump to deliver insulin intelligently, in order to control blood glucose within the normal range. The closed-loop feedback system was studied for its capability in maintaining the blood glucose levels of diabetic rats under various physiological conditions. The utility of the intelligent feedback system was successfully demonstrated on diabetic rats for controlling the blood glucose levels within the normal range. The minisystem is wearable, small, cost-effective, precise, stable and painless. It is anticipated that this approach opens a new paradigm for the development of closed-loop diabetes minisystems and may lead to a compelling future for diabetes management.Keywords
Funding Information
- Peking University First Hospital (2022CR83)
- National Key Research and Development Program of China (2018YFB1307301)
- Chinese Academy of Medical Sciences Initiative for Innovative Medicine (2019-I2M-5-046, 2020-JKCS-009)
- National Natural Science Foundation of China (52072007, 82130021)
This publication has 64 references indexed in Scilit:
- Feasibility of Closed-Loop Insulin Delivery in Type 2 Diabetes: A Randomized Controlled StudyDiabetes Care, 2014
- Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose BiosensorPLOS ONE, 2013
- Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trialCanadian Medical Association Journal, 2013
- An implantable MEMS micropump system for drug delivery in small animalsBiomedical Microdevices, 2012
- Closed-loop insulin delivery: from bench to clinical practiceNature Reviews Endocrinology, 2011
- Pregnancy and Diabetes Management: Advances and ControversiesClinical Chemistry, 2011
- Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 DiabetesNew England Journal of Medicine, 2010
- An electrochemical intraocular drug delivery deviceSensors and Actuators A: Physical, 2008
- Dependence of the estimated diffusion coefficient of LixWO3 films on the scan rate of cyclic voltammetry experimentsSolid State Ionics, 2007
- In VivoMonitoring the Changes of Interstitial pH and FAD/NADH Ratio by Fluorescence Spectroscopy in Healing Skin WoundsPhotochemistry and Photobiology, 2006