Electron temperature profile reconstructions from multi-energy SXR measurements using neural networks
- 7 August 2013
- journal article
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 55 (9) , 095015
Abstract
Neural networks have been implemented to reconstruct electron temperature profiles from multi-energy soft-x-ray (ME-SXR) arrays and other plasma diagnostics with fast time resolution. On NSTX, electron temperature profiles are measured with a Thomson scattering diagnostic at 60 Hz, a speed limited by the repetition rate of the lasers. By training a neural network to match fast (>10 kHz) x-ray data with Te profiles from Thomson scattering, the ME-SXR diagnostic can be used to produce Te profiles with high time resolution. In particular, a new ME-SXR system will be used in conjunction with a new laser blow-off impurity injection system to measure cold pulse propagation in NSTX-U plasmas for direct, perturbative heat transport measurements. Synthetic ME-SXR data were used to optimize performance of the neural networks and study the impact of including data from various diagnostics in the networks. Initial tests on data from a previous-generation ME-SXR diagnostic on NSTX have proven successful.Keywords
This publication has 31 references indexed in Scilit:
- Compact “diode-based” multi-energy soft x-ray diagnostic for NSTXReview of Scientific Instruments, 2012
- Central electron temperature estimations of TJ-II neutral beam injection heated plasmas based on the soft x ray multi-foil techniqueReview of Scientific Instruments, 2012
- Fast electron temperature measurements using a “multicolor” optical soft x-ray arrayJournal of Applied Physics, 2007
- A ‘multi-colour’ SXR diagnostic for time and space-resolved measurements of electron temperature, MHD activity and particle transport in MCF plasmasPlasma Physics and Controlled Fusion, 2007
- Two-dimensional time resolved measurements of the electron temperature in MSTReview of Scientific Instruments, 2006
- “Optical” soft x-ray arrays for fluctuation diagnostics in magnetic fusion energy experimentsReview of Scientific Instruments, 2004
- Operation of the NSTX Thomson scattering systemReview of Scientific Instruments, 2003
- Exploration of spherical torus physics in the NSTX deviceNuclear Fusion, 2000
- An optimized multifoil soft x-ray spectrometer for the determination of the electron temperature with high time resolutionReview of Scientific Instruments, 1999
- Multichord time resolved electron temperature measurements by the X-ray absorber foil method on TFTRNuclear Fusion, 1987