Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT
- 1 August 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1016) , 1134-1139
Abstract
Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[18F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and Monte Carlo simulations on an anthropomorphic phantom, the whole-body effective dose associated with LDCT was determined for the eight CT scanners used in the trial. A value of 7 mSv was assigned to FDG-PET while the measured mean effective dose of CT-guided FNAB was 1.5 mSv. The mean collective effective dose in the 1406 subjects ranged between 8.75 and 9.36 Sv and the mean effective dose to the single subject over 4 years was between 6.2 and 6.8 mSv (range 1.7–21.5 mSv) according to the cranial–caudal length of the LDCT volume. 77.4% of the dose was owing to annual LDCT and 22.6% to further investigations. Considering the nominal risk coefficients for stochastic effects after exposure to low-dose radiation according to the National Radiological Protection Board, International Commission on Radiological Protection (ICRP) 60, ICRP103 and Biological Effects of Ionizing Radiation VII, the mean number of radiation-induced cancers ranged between 0.12 and 0.33 per 1000 subjects. The individual effective dose to participants in a 4-year lung cancer screening programme with annual LDCT is very low and about one-third of the effective dose that is associated with natural background radiation and diagnostic radiology in the same time period.Keywords
This publication has 19 references indexed in Scilit:
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningThe New England journal of medicine, 2011
- UK Lung Screen (UKLS) nodule management protocol: modelling of a single screen randomised controlled trial of low-dose CT screening for lung cancerThorax, 2011
- Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanningThorax, 2010
- Lung cancer screening updateCurrent Opinion in Pulmonary Medicine, 2009
- The Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental DataRadiology, 2009
- Low-dose lung computed tomography screening before age 55: estimates of the mortality reduction required to outweigh the radiation-induced cancer riskJournal of Medical Screening, 2008
- Lung cancer screening with low-dose computed tomography: A non-invasive diagnostic protocol for baseline lung nodulesLung Cancer, 2008
- 20 years of patient dose studies: where should we go from here?British Journal of Radiology, 2005
- Radon in homes and risk of lung cancer: collaborative analysis of individual data from 13 European case-control studiesBMJ, 2004
- A Consensus Statement of the Society of Thoracic RadiologyJournal of Thoracic Imaging, 2001