Neutron-Irradiation Testing of FPGA-Embedded Hadron Fluence Sensors
Open Access
- 10 April 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (5) , 774-781
Abstract
Hadron fluence monitors based on static random access memories (SRAMs) are being used at CERN and have been proposed for proton therapy facilities. Some of the limitations of the state of the art are related to the usage of separate components for sensing upsets and for reading them out, as these increase the power consumption, the board complexity and its size. Moreover, in some cases, due to radiation-tolerance requirements, the readout logic is fixed and it cannot be updated once the system has been implemented. In this work, we show how to overcome the mentioned limitations by using an SRAM-based field programmable gate array (FPGA) for implementing both the sensitive element (the configuration SRAM) and the readout logic (the firmware in the fabric). In fact, we describe the implementation of a compact, reprogrammable, low-power, actively self-reading hadron fluence sensor realized by means of a Xilinx Artix-7 FPGA. Moreover, we present the customized radiation-hardening-by-design techniques adopted for the readout logic. We irradiated two sensor prototypes at the Jožef Stefan Institute’s TRIGA Mark II research reactor, under different neutron spectra and flux conditions. We discuss our results, which include the measurements of the radiation tolerance, the single event upset cross section of the configuration SRAM, the sensitivity to thermal neutrons, and the failure cross section of the readout logic.Keywords
Funding Information
- Istituto Nazionale di Fisica Nucleare (INFN), Italy, within the framework of Commissione Scientifica Nazionale V
- EU Horizon 2020 AIDAInnova (101004761)
This publication has 22 references indexed in Scilit:
- Radiation effects in reconfigurable FPGAsSemiconductor Science and Technology, 2017
- Embedded Detection and Correction of SEU Bursts in SRAM Memories Used as Radiation DetectorsIEEE Transactions on Nuclear Science, 2016
- High-Resolution Synthesizable Digitally-Controlled Delay LinesIEEE Transactions on Nuclear Science, 2015
- Design and characterization of an SRAM-based neutron detector for particle therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- TID Response of Various Field Programmable Gate Arrays and Memory Devices2015
- Qualification and Characterization of SRAM Memories Used as Radiation Sensors in the LHCIEEE Transactions on Nuclear Science, 2014
- Computational analysis of irradiation facilities at the JSI TRIGA reactorApplied Radiation and Isotopes, 2012
- Hadron fluence measurements with LiF-TLD sensors at the proton synchrotron accelerator at CERNRadiation Measurements, 2010
- Experimental and theoretical study of the neutron dose produced by carbon ion therapy beamsRadiation Protection Dosimetry, 2007
- Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation fieldNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001