The Reliability and Accuracy of a Fall Risk Assessment Procedure Using Mobile Smartphone Sensors Compared with a Physiological Profile Assessment
Authors:
- José-Francisco Pedrero-SánchezJPJosé-Francisco Pedrero-Sánchez
- Helios De-Rosario-MartínezHDHelios De-Rosario-Martínez
- Enrique Medina-RipollEMEnrique Medina-Ripoll
- David Garrido-JaénDGDavid Garrido-Jaén
- Pilar Serra-AñóPilar Serra-Añó
- Sara Mollà-CasanovaSMSara Mollà-Casanova
- Juan López-PascualJLJuan López-Pascual
Open Access
Abstract
Falls in older people are a major health concern as the leading cause of disability and the second most common cause of accidental death. We developed a rapid fall risk assessment based on a combination of physical performance measurements made with an inertial sensor embedded in a smartphone. This study aimed to evaluate and validate the reliability and accuracy of an easy-to-use smartphone fall risk assessment by comparing it with the Physiological Profile Assessment (PPA) results. Sixty-five participants older than 55 performed a variation of the Timed Up and Go test using smartphone sensors. Balance and gait parameters were calculated, and their reliability was assessed by the (ICC) and compared with the PPAs. Since the PPA allows classification into six levels of fall risk, the data obtained from the smartphone assessment were categorised into six equivalent levels using different parametric and nonparametric classifier models with neural networks. The F1 score and geometric mean of each model were also calculated. All selected parameters showed ICCs around 0.9. The best classifier, in terms of accuracy, was the nonparametric mixed input data model with a 100% success rate in the classification category. In conclusion, fall risk can be reliably assessed using a simple, fast smartphone protocol that allows accurate fall risk classification among older people and can be a useful screening tool in clinical settings.Keywords
Funding Information
- Ministerio de Ciencia e Innovación (CER-20211003, PID2021-125694OB-I00, CIAICO/2021/215, INV19-01-13-07)
- State Plan for Scientific and Technical Research and Innovation (Knowledge Generation) (CER-20211003, PID2021-125694OB-I00, CIAICO/2021/215, INV19-01-13-07)
- Generalitat Valenciana, Conselleria d’Innovació, Universitats, Ciència i Societat (CER-20211003, PID2021-125694OB-I00, CIAICO/2021/215, INV19-01-13-07)
- Universitat de València (CER-20211003, PID2021-125694OB-I00, CIAICO/2021/215, INV19-01-13-07)
This publication has 52 references indexed in Scilit:
- Review of fall risk assessment in geriatric populations using inertial sensorsJournal of NeuroEngineering and Rehabilitation, 2013
- Evaluation of Accelerometer-Based Fall Detection Algorithms on Real-World FallsPLOS ONE, 2012
- Effect of Lower Limb Strength on Falls and Balance of the ElderlyAnnals of Rehabilitation Medicine, 2012
- An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallersPhysiological Measurement, 2011
- A retrospective analysis of balance control parameters in elderly fallers and non-fallersClinical Biomechanics, 2010
- A body-fixed-sensor-based analysis of power during sit-to-stand movementsGait & Posture, 2010
- IMU: Inertial sensing of vertical CoM movementJournal of Biomechanics, 2009
- Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurementElectronics Letters, 2006
- Psychometric Comparisons of the Timed Up and Go, One‐Leg Stand, Functional Reach, and Tinetti Balance Measures in Community‐Dwelling Older PeopleJournal of the American Geriatrics Society, 2004
- Risk Factors for Falls among Elderly Persons Living in the CommunityNew England Journal of Medicine, 1988