Prospective Effectiveness of Stapes Surgery for Otosclerosis in a Multicenter Audit Setting
Authors:
- Vincent Van RompaeyVRVincent Van Rompaey
- Matthew YungMYMatthew Yung
- Jozef ClaesJCJozef Claes
- Rudolf HäuslerRHRudolf Häusler
- Christian MartinCMChristian Martin
- Thomas SomersTSThomas Somers
- Erwin OffeciersEOErwin Offeciers
- Jozsef PytelJPJozsef Pytel
- Jacek SkladzienJSJacek Skladzien
- Paul Van de HeyningPHPaul Van de Heyning
- 1 December 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 30 (8) , 1101-1110
Abstract
The Common Otology Database (COD) is a joint effort by an international group of otologists to organize audit with a standardized reporting method in middle ear surgery. The first results on hearing outcome of the COD are presented in this article. The primary objective was to confirm the validity of the benchmark group by comparing hearing outcome results with previously reported results. The secondary objective was to describe the population, technical aspects, and hearing outcomes of stapes surgery. Nonrandomized prospective multicenter audit. Twenty tertiary-referral otologic centers. Primary and revision stapes operations in patients with otosclerosis. Air-bone gap (ABG), bone-conduction (BC) thresholds, and air-conduction (AC) thresholds were evaluated at 3 and 12 months according to the guidelines of the Committee on Hearing and Equilibrium for the evaluation of conductive hearing loss. Raw data were displayed in an Amsterdam Hearing Evaluation Plot. In primary stapes surgeries, the postoperative ABG was closed to 10 dB or less in 63.6% and to 20 dB or less in 92.6% (median, 8.75 dB). In revision stapes surgeries, the postoperative ABG was closed to 10 dB in 41.2% and to 20 dB in 76.5% of cases (median, 11.25 dB). The overall mean postoperative ABG at 12 months was 10.38 dB compared with 28.75 dB preoperatively. Using laser to perform the fenestration results in a less pronounced BC improvement when compared with procedures without laser assistance. No statistically significant difference in ABG pure-tone average at 3 months could be demonstrated between the different prosthesis types. Results of hearing outcome are similar to previous, primarily retrospective, single-center studies. Our data confirm the effectiveness of stapes surgery in patients with otosclerosis.Keywords
This publication has 14 references indexed in Scilit:
- International Common Otology Database: Taste Disturbance After Stapes SurgeryOtology & Neurotology, 2008
- Stapedotomy with Microdrill or Carbon Dioxide Laser: Influence on Inner Ear FunctionAnnals of Otology, Rhinology & Laryngology, 2006
- Surgical Findings and Long-Term Hearing Results in 3,050 Stapedotomies for Primary OtosclerosisOtology & Neurotology, 2006
- Surgical treatment of otosclerosis in medical residency trainingBrazilian Journal of Otorhinolaryngology, 2006
- An International Otology DatabaseOtology & Neurotology, 2005
- Pragmatic controlled clinical trials in primary care: the struggle between external and internal validityBMC Medical Research Methodology, 2003
- Stapes surgery in relation to age.Clinical Otolaryngology, 2003
- Stapedectomy Versus Stapedotomy: Comparison of Results With Long‐Term Follow‐upThe Laryngoscope, 2002
- Efficacy of Evaluation of Audiometric Results After Stapes Surgery in Otosclerosis. I. The Effects of Using Different Audiologic Parameters and Criteria on Success RatesOtolaryngology–Head and Neck Surgery, 2001
- Committee on Hearing and Equilibrium Guidelines for the Evaluation of Results of Treatment of Conductive Hearing Loss∗Otolaryngology–Head and Neck Surgery, 1995