Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy
Authors:
- Chris J DiederichCDChris J Diederich
- William H NauWNWilliam H Nau
- Harcharan GillHGHarcharan Gill
- Donna M BouleyDBDonna M Bouley
- Bruce DanielBDBruce Daniel
- Viola RiekeVRViola Rieke
- R Kim ButtsRBR Kim Butts
- Graham SommerGSGraham Sommer
- 5 January 2004
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (2) , 189-204
Abstract
Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either 90 degrees sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n = 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the 90 degrees tubular applicator (9-15 W, 12 min, 8 MHz) produced coagulated zones covering an 80 degrees wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, approximately 8 MHz) generated thermal lesions of approximately 30 degrees extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 degrees each) demonstrated controllable coagulation of a 270 degrees contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.Keywords
This publication has 31 references indexed in Scilit:
- Interstitial ultrasound heating applicator for MR-guided thermal therapyPhysics in Medicine & Biology, 2001
- MRI study of immediate cell viability in focused ultrasound lesions in the rabbit brainJournal of Magnetic Resonance Imaging, 2001
- Transrectal High-Intensity Focused Ultrasound: Minimally Invasive Therapy of Localized Prostate CancerJournal of Endourology, 2000
- Current Status of Minimally Invasive Treatment Options for Localized Prostate CarcinomaEuropean Urology, 2000
- Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapyInternational Journal of Hyperthermia, 2000
- Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapyIEEE Transactions on Biomedical Engineering, 2000
- Axial control of thermal coagulation using a multi-element interstitial ultrasound applicator with internal coolingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2000
- Prostate Cancer: MR Imaging and Thermometry during Microwave Thermal Ablation-Initial ExperienceRadiology, 2000
- Transrectal high-intensity focused ultrasound using the Ablatherm device in the treatment of localized prostate carcinomaUrology, 1999
- Transurethral ultrasound array for prostate thermal therapy: initial studiesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996