Accuracy of the Diffusive Gradients in Thin-Films Technique: Diffusive Boundary Layer and Effective Sampling Area Considerations
Authors:
- 3 May 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (11) , 3780-3787
Abstract
When using the diffusive gradients in thin-films (DGT) technique in well-stirred solutions, the diffusive boundary layer has generally been ignored on the assumption that it is negligibly thin compared to the total thickness of Δg, i.e., the sum of the thickness of the prefilter and diffusive gel. Deployment of devices with different diffusive layer thicknesses showed that the thickness of the DBL was ∼0.23 mm in moderate to well-stirred solutions, but substantially thicker in poorly or unstirred solutions. Measurement of the distribution of Cd in the DGT resin gel at high spatial resolution (100 μm) using laser ablation inductively coupled plasma mass spectrometry showed that the effective sampling window had a larger diameter (2.20 cm) than the geometric diameter of the exposure window (2.00 cm). Lateral diffusion in the gel, which had previously been neglected, therefore increased the effective surface area of the device by ∼20%. The concentrations measured by DGT agreed well with the known concentrations in standard solutions for all diffusion layer thicknesses, when the effective area and the appropriate diffusive boundary layer (DBL) were used. The extent of the error associated with neglecting the DBL and using the geometric window area depends on the gel layer thickness and the true thickness of the DBL, as determined by the deployment geometry and flow regime. When DGT measurements were made in well-stirred solutions using a 0.80-mm diffusive gel, the effect of neglecting the DBL and using the inappropriate geometric area offset each other, with the error being <±10%. For precise measurements, and especially work involving speciation or kinetic measurements, where DGT devices with different diffusive gel layer thicknesses are deployed, it is necessary to use the effective area and the appropriate DBL thickness in the full DGT equation, which allows for the use of layer-specific diffusion coefficients.Keywords
This publication has 7 references indexed in Scilit:
- Diffusion coefficients of metals and metal complexes in hydrogels used in diffusive gradients in thin filmsAnalytica Chimica Acta, 2006
- Trace Metal Measurements in Low Ionic Strength Synthetic Solutions by Diffusive Gradients in Thin FilmsAnalytical Chemistry, 2005
- Performance Study of Diffusive Gradients in Thin Films for 55 ElementsAnalytical Chemistry, 2003
- In Situ Measurements of Dissociation Kinetics and Labilities of Metal Complexes in Solution Using DGTEnvironmental Science & Technology, 2003
- Effect of solution composition, flow and deployment time on the measurement of trace metals by the diffusive gradient in thin films techniqueAnalytica Chimica Acta, 2001
- In situ measurements of labile Cu, Cd and Mn in river waters using DGTScience of The Total Environment, 1999
- In situ speciation measurements of trace components in natural waters using thin-film gelsNature, 1994