Analysis and Comparative Study on the Performance between Standard and High Efficiency Induction Machines operating as Self - Excited Induction Generators
Authors:
- 1 November 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1313-1318
Abstract
This paper proposes the performance analysis and comparative study between standard and high efficiency squirrel cage self- excited induction generators (SEIG). Consideration of capacitance of SEIG based on equivalent circuit model is given. Testing and performance comparison under dynamic and steady state conditions for both pure resistive and resistive - inductive load conditions have been made. The interpretation of experimental results can be guidelines for effective design and development of SEIG for wind energy applications.Keywords
This publication has 6 references indexed in Scilit:
- Self-excited induction generator with simple voltage regulation scheme for wind energy2005
- Capacitance requirements of self-excited induction generatorsIEEE Transactions on Energy Conversion, 1993
- A step towards improvements in the characteristics of self excited induction generatorIEEE Transactions on Energy Conversion, 1993
- Comparative study on the performance of a commercially designed induction generator with induction motors operating as self excited induction generatorsIEE Proceedings C Generation, Transmission and Distribution, 1993
- Studies on the use of conventional induction motors as self-excited induction generatorsIEEE Transactions on Energy Conversion, 1988
- Analysis of self-excited induction generatorsIEE Proceedings C Generation, Transmission and Distribution, 1982