Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter
Authors:
- Takushi KawamoritaTKTakushi Kawamorita
- Hiroshi UozatoHUHiroshi Uozato
- Kazutaka KamiyaKKKazutaka Kamiya
- Kimiya ShimizuKSKimiya Shimizu
- 1 April 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (4) , 617-624
Abstract
To evaluate the relationship between the horizontal ciliary sulcus diameter and anterior chamber diameter measured by 35 MHz ultrasound biomicroscopy (UBM) and the horizontal corneal diameter (white to white [WTW]) measured by scanning-slit topography and to assess the repeatability (intraexaminer difference) of the 2 methods. Department of Orthoptics and Visual Science, Kitasato University School, Sagamihara, Japan. The repeatability and agreement of UBM and scanning-slit topography were assessed using the intraclass correlation (ICC) and the Bland and Altman method (ie, mean difference and 95% limits of agreement [LoA]). Thirty-one normal eyes of 31 subjects (mean age 22.6 years +/- 4.8 [SD]) were evaluated. The mean differences between the repeated measurements were as follows: ciliary sulcus diameter, -0.05 mm (95% LoA, -0.38 to 0.28 mm); anterior chamber diameter, 0.02 mm (95% LoA, -0.42 to 0.45 mm); and WTW diameter, -0.02 mm (95% LoA, -0.18 to 0.13 mm). The agreement between ciliary sulcus diameter and WTW diameter was poor (ICC, 0.679). The mean difference was 0.41 mm (95% LoA, -0.46 to 1.28 mm). The agreement between the ciliary sulcus diameter and anterior chamber diameter was high (ICC, 0.918). The mean difference was 0.13 mm (95% LoA, -0.41 to 0.67 mm). Results suggest that direct measurement of the ciliary sulcus by UBM would reduce the percentage of complications related to intraocular lens sizing over the percentage when sizing is based on WTW diameter.Keywords
This publication has 14 references indexed in Scilit:
- Correlation of Anterior Chamber Angle and Ciliary Sulcus Diameters With White-to-White Corneal Diameter in High Myopes Using Artemis VHF Digital UltrasoundJournal of Refractive Surgery, 2009
- Metaanalysis of cataract development after phakic intraocular lens surgeryJournal of Cataract & Refractive Surgery, 2008
- Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurementsJournal of Cataract & Refractive Surgery, 2008
- Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: Evaluation of equivalenceJournal of Cataract & Refractive Surgery, 2008
- Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound BiomicroscopyOphthalmology, 2007
- Ultrasound Biomicroscopy for Determining Visian Implantable Contact Lens Length in Phakic IOL ImplantationJournal of Refractive Surgery, 2007
- Phakic Intraocular LensesSurvey of Ophthalmology, 2005
- Magnetic resonance imaging and Orbscan assessment of the anterior chamberJournal of Cataract & Refractive Surgery, 2005
- Correlation between different measurements within the eye relative to phakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Predicting sulcus size using ocular measurementsJournal of Cataract & Refractive Surgery, 2001