SHORT-TERM SAFETY OF 23-GAUGE SINGLE-STEP TRANSCONJUNCTIVAL VITRECTOMY SURGERY
Authors:
- 1 November 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 29 (10) , 1486-1490
Abstract
Purpose: The purpose of this study was to report the safety profile of the Alcon 23-gauge single-step preloaded transconjunctival vitrectomy system. Methods: This was a retrospective case series examining 118 eyes of 114 patients that underwent 23-gauge vitrectomy between July and November 2007. Patients were observed postoperatively for a minimum of 6 weeks. Main outcome measures were postoperative intraocular pressure (IOP), intraoperative complications, and postoperative adverse events. Results: The mean postoperative Day 1 IOP was 14.3 ± 6.6 mmHg (median, 13 mmHg; range, 2–38 mmHg) and Month 1 IOP was 15.8 ± 5.9 mmHg (median, 15 mmHg; range, 6–52 mmHg). Two eyes (1.7%) developed choroidal effusions. Four eyes (3.4%) developed intraoperative horseshoe tears. No retinal detachments or endophthalmitis occurred. Four eyes (3.4%) had postoperative hypotony. Intraoperative wound leak after cannula removal requiring a sclerotomy suture occurred in 38% of patients: 35 eyes requiring closure of 1 cannula site (29.6%), 8 eyes (6.8%) requiring closure of 2 cannula sites, and 2 eyes (1.7%) requiring closure of all 3 cannula sites. Conclusion: The Alcon 23-gauge single step preloaded transconjunctival vitrectomy system has few safety issues. Sclerotomy leaks after cannula removal are common, with 38% of eyes requiring suture closure of at least 1 cannula site.Keywords
This publication has 17 references indexed in Scilit:
- The incidence of endophthalmitis following transconjunctival sutureless 25- vs 20-gauge vitrectomyEye, 2008
- Acute endophthalmitis after 25-gauge sutureless vitrectomyInternational Ophthalmology, 2007
- 25-Gauge transconjunctival sutureless vitrectomyCurrent Opinion in Ophthalmology, 2007
- Incidence of Complications in 25-Gauge Transconjunctival Sutureless Vitrectomy Based on the Surgical IndicationsOphthalmic Surgery, Lasers and Imaging Retina, 2007
- Postoperative Complications Associated With 25-Gauge Pars Plana VitrectomyOphthalmic Surgery, Lasers and Imaging Retina, 2007
- ENDOPHTHALMITIS AFTER 25-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMYRetina, 2006
- Longer-term Outcomes of Transconjunctival Sutureless 25-gauge VitrectomyAmerican Journal of Ophthalmology, 2005
- Outcomes of 140 Consecutive Cases of 25-Gauge Transconjunctival Surgery for Posterior Segment DiseaseOphthalmology, 2005
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002