To fully optimize the operation of a high gain free-electron laser facility and offer opportunities for time-resolved experiments, a highly accurate synchronization between an electron bunch and a seeded laser is required. Thus, a high-precision and high-resolution beam arrival and flight time measurement system is built at the Shanghai soft X-ray free-electron laser (SXFEL) facility. For the SXFEL, a beam arrival time resolution better than 100 fs is required. A phase cavity-based detection scheme for this measurement has already been adopted at the SXFEL. To further optimize system performance, the impacts of clock jitter, trigger jitter, and signal analysis length on the measurement uncertainties are analyzed, and related subsystems are upgraded and optimized accordingly. The beam arrival time is successfully measured, and the initial measurement uncertainty is better than 45 fs. Furthermore, a dual-cavity mixing scheme is realized to measure the beam flight time or pseudo beam arrival time, and the measurement resolution of the beam flight time using this technique is 13 fs.Keywords
Funding Information
- National Key Research and Development Program of China (2016YFA0401903)
- National Natural Science Foundation of China (11575282)
- Young and Middle-Aged Leading Scientists, Engineers and Innovators through the Ten Thousand Talent Program
This publication has 7 references indexed in Scilit:
- Dual-cavity beam arrival time monitor design for the Shanghai soft X-ray FEL facilityNuclear Science and Techniques, 2019
- Review of fully coherent free-electron lasersNuclear Science and Techniques, 2018
- SXFEL: A Soft X-ray Free Electron Laser in ChinaSynchrotron Radiation News, 2017
- A single stage EEHG at SXFEL for narrow-bandwidth soft X-ray generationScience Bulletin, 2016
- Advanced diagnosis of the temporal characteristics of ultra-short electron beamsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Single-bunch emittance preservation in the presence of trajectory jitter for FERMI@elettra-seeded FELNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Cavity beam position monitorsAIP Conference Proceedings, 1998