Fast Scan Cyclic Voltammetry (FSCV) at high aspect ratio carbon microelectrodes shows adequate high temporal and spatial resolution for in vivo analysis of catecholamines. Though the presence of their surface heterogeneities has been recognized since their earliest introduction for in vivo measurements in the brain, the kinetic consequences on the measurements have not been investigated and FSCV measurements are treated based on pre- and post-calibrations. We establish here that surface heterogeneities play a consequent dynamic role on the oxidation of dopamine taken as an example of catecholamines. Hence, the FSCV current peak intensities do not scale with the scan rate v or its square root. This is rationalized with a simple model involving a co-existence of at least two types of surface nanodomains with different electrochemical reactivities and different time responses. At low scan rates (−1) dopamine molecules that initially adsorbed onto non-electroactive nanodomains have enough time to migrate toward highly electroactive ones so all molecules initially adsorbed on the whole electrode surface may be oxidized during one FSCV cycle. Current peak intensities then increase proportionally to the scan rate. However, above 100 V s−1, dopamine migration between sites starts to be kinetically limited so that FSCV current peak intensities do not increase any more proportionally to the scan rate. Ultimately, i.e., above 1000 V s−1, the dopamine exchange between sites is almost totally blocked so only dopamine molecules initially adsorbed on the electroactive surface nanodomains may be oxidized; the current peak intensities then increase again proportionally with the scan rate though with a smaller slope than that observed at small scan rates. Since carbon fibers with large aspect ratios are frequently used in brain investigations, this effect should be a concern when extracting quantitative results even when each carbon fiber response is properly pre- or post-calibrated using the exact CV waveform and scan rate used during the in vivo measurements.Keywords
Funding Information
- European Union (H2020-MSCA-IF-2014, grant agreement 660339 (eADAM))
- CNRS LIA France (LIA CNRS NanoBioCatEchem)
This publication has 59 references indexed in Scilit:
- New theoretical insights into the competitive roles of electron transfers involving adsorbed and homogeneous phasesJournal of Electroanalytical Chemistry, 2013
- In vivo voltammetric monitoring of catecholamine release in subterritories of the nucleus accumbens shellNeuroscience, 2010
- Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animalsNature Methods, 2009
- Monitoring Rapid Chemical Communication in the BrainChemical Reviews, 2008
- Electrochemical dopamine detection: Comparing gold and carbon fiber microelectrodes using background subtracted fast scan cyclic voltammetryJournal of Electroanalytical Chemistry, 2008
- Control of reactivity at carbon electrode surfacesColloids and Surfaces A: Physicochemical and Engineering Aspects, 1994
- Transfer diffusion. II. Kinetics of electron exchange reaction between ferrocene and ferricinium ion in alcoholsThe Journal of Physical Chemistry, 1971
- Transfer diffusion. I. TheoreticalThe Journal of Physical Chemistry, 1971
- Electronic conduction in aqueous solutionThe Journal of Physical Chemistry, 1968
- Potential-sweep chronoamperometry theory of kinetic currents in the case of a first order chemical reaction preceding the electron-transfer processElectrochimica Acta, 1963