Pupil Size in Refractive Surgery Candidates
Authors:
- Renato AmbrósioRARenato Ambrósio
- Steven E WilsonSWSteven E Wilson
- 1 July 2004
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 20 (4) , 337-342
Abstract
PURPOSE: To assess pupil size measurements obtained under scotopic and mesopic conditions with the Procyon pupillometer and under photopic conditions with the Humphrey videokeratographer. METHODS: The pupil sizes of 96 candidates for refractive surgery (192 eyes) were measured with the Procyon pupillometer PS2000 SA and the Humphrey Atlas 992 corneal topographer. Anisocoria and pupillary unrest were analyzed according to gender (two groups: 51 females and 45 males), age (five groups: 20 to 30 yr, 31 to 40 yr, 41 to 50 yr, 51 to 60 yr, older than 60 yr) and level of refraction (five groups: >-6.00 D SE, -6.00 to ?3.00 D SE, -3.00 to 0 D SE, 0 to +2.50 D SE, +2.50 to +5.00 D SE). RESULTS: The median value of pupil diameter measured with the Procyon pupillometer at the scotopic (0.04 lux), mesopic-low (0.4 lux), and mesopic-high (4 lux) levels of illumination were 6.54 ? 0.88 mm; 5.62 ? 0.95 mm, and 4.09 ? 0.76 mm, respectively. The median pupil size with the Humphrey topographer was 3.65 ? 0.62 mm. Pupillary unrest was highest at the mesopic-high level of illumination, with a median value of 0.31 ? 0.34 mm. Median pupil size measured with both instruments at all light levels dropped significantly after the fifth decade of life (P<.05, ANOVA). CONCLUSIONS: The Procyon pupillometer and Humphrey videokeratographer revealed an inverse correlation between the pupil size and the age, but no relationship with gender or level of refraction. The Procyon pupillometer provides an objective method for measuring pupil size at controlled light levels with a permanent printed record. [J Refract Surg 2004;20:337-342]Keywords
This publication has 21 references indexed in Scilit:
- Quality of vision after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2003
- Defining Mesopic and ScotopicJournal of Cataract & Refractive Surgery, 2003
- Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameterJournal of Cataract & Refractive Surgery, 2003
- Colvard Pupillometer Measurement of Scotopic Pupil Diameter in Emmetropes and MyopesJapanese Journal of Ophthalmology, 2002
- Night Vision Disturbances After Corneal Refractive SurgerySurvey of Ophthalmology, 2002
- Use of a digital infrared pupillometer to assess patient suitability for refractive surgeryJournal of Cataract & Refractive Surgery, 2002
- LettersJournal of Cataract & Refractive Surgery, 1998
- LettersJournal of Cataract & Refractive Surgery, 1998
- The relationship between pupil diameter and decentration in myopiaEye, 1997
- Pupil diameter and the principal rayJournal of Cataract & Refractive Surgery, 1992