Abstract
Clean food contact surfaces are important in reducing the likelihood of foodborne disease transmission. The goal of this study was to assess and compare baseline cleanliness of food contact and environmental surfaces in retail food establishments by using ATP bioluminescence (ATP-B), visual assessment, and surface contact plates. Four hundred eighty-nine surface samples were collected from three food service establishments at the University of Minnesota-Twin Cities (Minneapolis) and analyzed for either ATP (252) or total aerobic plate count bacteria (237). ATP levels ranged from a minimum of 4 relative light units (RLU; 0.60 log RLU) on a clean slicer to a maximum of 506,618 RLU (5.77 log RLU) on a dirty cutting board. The overall mean was 1,950 RLU (3.29 log RLU). Cutting boards had the highest ATP levels (mean, 5,495 RLU or 3.74 log RLU; median, 6,761 RLU or 3.83 log RLU). Of the 128 samples judged visually clean at the time of sampling, 70.3 % failed ATP-B testing. Sixty-one (26 % ) of the 237 total aerobic plate count samples yielded counts of over 125 CFU/50 cm(2) (failed), and of those that failed, 40 % were assessed as visually clean before sampling. The highest average counts in CFU/50 cm(2) were found on slicers (104) and cutting boards (87). The results of this study suggest that the current practice of evaluating food contact surface cleanliness by sight and touch to meet regulatory requirements might be inadequate. ATP-B testing may be an efficient tool to facilitate creation, implementation, and validation of more effective food contact surface cleaning in food establishments.Keywords
This publication has 20 references indexed in Scilit:
- The detection of food soils and cells on stainless steel using industrial methods: UV illumination and ATP bioluminescenceInternational Journal of Food Microbiology, 2008
- A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfacesJournal of Hospital Infection, 2008
- Comparison of adenosine triphosphate (ATP) bioluminescence and aerobic plate counts (APC) on plastic cutting boards*Journal of Foodservice, 2007
- Monitoring the effectiveness of cleaning in four British hospitalsAmerican Journal of Infection Control, 2007
- The safety of wooden cutting boardsBritish Food Journal, 2007
- Persistence of Campylobacter jejuni on surfaces in a processing environment and on cutting boardsLetters in Applied Microbiology, 2005
- Use of audit tools to evaluate the efficacy of cleaning systems in hospitalsAmerican Journal of Infection Control, 2003
- An assessment of cleaning regimes and standards in butchers' shopsInternational Journal of Environmental Health Research, 2001
- An evaluation of hospital cleaning regimes and standardsJournal of Hospital Infection, 2000
- Assessment of cleaning and disinfection in the food industry with the rapid ATP-bioluminescence technique combined with the tissue fluid contamination test and a conventional microbiological methodInternational Journal of Food Microbiology, 1993