Adhesion measurement of highly-ordered TiO2 nanotubes on Ti-6Al-4V alloy
Open Access
- 1 January 2017
- journal article
- Published by National Library of Serbia in Processing and Application of Ceramics
- Vol. 11 (4) , 311-321
Abstract
Self-assembled nanotubular arrays on Ti alloys could be used for more effective implantable devices in various medical approaches. In the present work, the adhesion of TiO2 nanotubes (TiO2 NTs) on Ti-6Al-4V (Ti64) was investigated by laser spallation and scratch test techniques. At first, electrochemical anodization was performed in an ammonium fluoride solution dissolved in a 90:10 ethane-1,2-diol (ethylene glycol) and water solvent mixture. This process was performed at room temperature (23?C) at a steady potential of 60 V for 1 h. Next, the TiO2 nanotubes layer was heat-treated to improve the adhesion of the coating. The formation of selforganized TiO2 nanotubes as well as the microstructural evolution, are strongly dependent on the processing parameters and subsequent annealing. From microscopic analysis, highly oriented arrays of TiO2 nanotubes were grown by thermal treatment for 90min at 500?C. Further heat treatment above 500?C led to the detachment of the nanotubes and the complete destruction of the nanotubes occurred at temperature above 700?C. Scratch test analysis over a constant scratch length (1000 ?m) indicated that the failure point was shifted from 247.4 to 557.9 ?m while the adhesion strength was increased from ~862 to ~1814mN after annealing at 500?C. The adhesion measurement determined by laser spallation technique provided an intrinsic adhesion strength of 51.4MPa for the TiO2 nanotubes on the Ti64 substrate.Keywords
This publication has 33 references indexed in Scilit:
- Effect of microstructural evolution on wettability and tribological behavior of TiO2 nanotubular arrays coated on Ti–6Al–4VCeramics International, 2015
- Enhanced osseointegration of titanium implants with nanostructured surfaces: An experimental study in rabbitsActa Biomaterialia, 2015
- Structural and mechanical characterization of Al/Al2O3 nanotube thin film on TiV alloyApplied Surface Science, 2014
- Wear and corrosion resistance of anti-bacterial Ti–Cu–N coatings on titanium implantsApplied Surface Science, 2014
- Measurement of the tensile strength of cell–biomaterial interface using the laser spallation techniqueActa Biomaterialia, 2008
- Microstructure and deformation behavior of biocompatible TiO2 nanotubes on titanium substrate☆Acta Biomaterialia, 2007
- Augmentation of cancellous screw fixation with hydroxyapatite composite resin (CAP)in vivoJournal of Biomedical Materials Research, 2000
- Measurement of interface strength by a laser spallation techniqueJournal of the Mechanics and Physics of Solids, 1992
- The scratch test: Different critical load determination techniquesSurface and Coatings Technology, 1988
- Scratch adhesion testing of hard coatingsThin Solid Films, 1983