Effect of electric-arc-induced ablation on corrosion behavior of pipeline steel under high-voltage direct current interference
Authors:
- 14 June 2022
- journal article
- research article
- Published by Emerald Publishing in Anti-Corrosion Methods and Materials
- Vol. 69 (5) , 481-489
Abstract
Purpose: The purpose of this study is to elucidate the effects of electric-arc-induced ablation on the corrosion behavior of pipeline steel in neutral and high pH environments. Design/methodology/approach: Electrochemical testing, an atmospheric-pressure immersion experiment and various techniques (e.g. scanning electron microscopy, energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy) were used to examine the effects of electric-arc-induced ablation on the corrosion behavior of pipeline steel in neutral and high pH environment. Findings: Electric-arc-induced ablation occurred preferentially in areas of inclusion. The corrosion resistance of an ablation pit was lower than that of non-ablation areas. In the neutral soil solution, general corrosion was the dominant corrosion that affected pipeline steel; the effect of ablation was small but pitting corrosion could still be induced. In a high pH environment, the samples without ablation were passivated, whereas the samples with ablation pits could not be passivated; the ablation pits were likely to develop pitting corrosion. Originality/value: Electric-arc-induced ablation can reduce the corrosion resistance of pipeline steel under high-voltage direct current interference.Keywords
This publication has 13 references indexed in Scilit:
- Corrosion behaviors of X70 steel under direct current interferenceAnti-Corrosion Methods and Materials, 2019
- Pipeline failures due to lightningEngineering Failure Analysis, 2016
- The protection of 500kV substation grounding grids with combined conductive coating and cathodic protectionAnti-Corrosion Methods and Materials, 2015
- Stray current corrosion in buried pipelineAnti-Corrosion Methods and Materials, 2011
- Pipeline Failure Results from Lightning Strike: Act of Mother Nature?Journal of Failure Analysis and Prevention, 2011
- BP neural network predictive model for stray current density of a buried metallic pipelineAnti-Corrosion Methods and Materials, 2010
- Estimation of the temperature rise in cylindrical conductors subjected to heavy 10/350μs lightning current impulsesElectric Power Systems Research, 2008
- Measurement of the rear‐face temperature of metals struck by lightning long‐duration currentsEuropean Transactions on Electrical Power, 2004
- Accelerating Effect and Critical pH Value of Occluded Cell Corrosion Within Pits, Crevices, or Stress Corrosion CracksCorrosion, 1988
- The Effects of High-Voltage DC Power Transmission Systems on Buried Metallic PipelinesIEEE Transactions on Industry and General Applications, 1971