Extended use of a percutaneous left-ventricular assist device without a heparin-based purge solution
- 1 November 2010
- journal article
- case report
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 67 (21) , 1825-1828
Abstract
Purpose The extended use of an Impella LP 2.5 percutaneous left-ventricular assist device (pVAD) without a heparin-based purge solution in a patient who developed cardiogenic shock after acute myocardial infarction (AMI) is described. Summary A 58-year-old Asian man with no history of cardiac disease, hypertension, or diabetes mellitus had an AMI and subsequent cardiogenic shock. He was started on dopamine and norepinephrine and transferred to a tertiary care center for rescue percutaneous coronary intervention (PCI). Given that his artery was patent with Thrombolysis In Myocardial Infarction 3 flow, PCI was not attempted. He had an ejection fraction of 25% and mid-distal anteroseptal akinesis. He was transferred to the intensive care unit on intra-aortic balloon pump (IABP) support. The patient’s condition continued to deteriorate, and an Impella LP 2.5 pVAD was inserted for additional hemodynamic support and as a bridge to definitive revascularization. To reduce the potential for medication error and decrease the patient’s bleeding risk, the purge solution was changed to 20% dextrose injection without heparin and continued at a rate of 15 mL/hr. The patient’s hemodynamic values improved, and the pVAD and IABP were continued for the next five days. The patient was successfully anticoagulated with i.v. heparin throughout the remainder of pVAD support. While the patient did develop hemolytic anemia during his device support, there were no thrombotic or bleeding complications. Conclusion An Impella LP 2.5 pVAD was used for 75 hours with a purge solution that contained no heparin. There were no thrombotic or bleeding complications.Keywords
This publication has 8 references indexed in Scilit:
- Incidence of early left ventricular thrombus after acute anterior wall myocardial infarction in the primary coronary intervention eraAmerican Heart Journal, 2009
- A Randomized Clinical Trial to Evaluate the Safety and Efficacy of a Percutaneous Left Ventricular Assist Device Versus Intra-Aortic Balloon Pumping for Treatment of Cardiogenic Shock Caused by Myocardial InfarctionJACC, 2008
- Safety and Feasibility of Elective High-Risk Percutaneous Coronary Intervention Procedures With Left Ventricular Support of the Impella Recover LP 2.5The American Journal of Cardiology, 2006
- High-risk percutaneous coronary intervention using the intracardiac microaxial pump ‘Impella Recover’Journal of Cardiovascular Medicine, 2006
- Trends in Management and Outcomes of Patients With Acute Myocardial Infarction Complicated by Cardiogenic ShockJAMA, 2005
- Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shockEuropean Heart Journal, 2005
- Miniature Intracardiac Assist Device Provides More Effective Cardiac Unloading and Circulatory Support During Severe Left Heart Failure Than Intraaortic Balloon PumpingChest, 2004
- Association of thrombocytopenia with the use of intra-aortic balloon pumpsThe American Journal of Medicine, 1998