Comparison study of dual-energy techniques in chest radiography
Authors:
- 1 March 2019
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10948, 109481E
Abstract
Dual-energy (DE) technology is useful in chest radiography because it can separate anatomical structures such as bone and soft tissue. The standard log subtraction (SLS), simple smoothing of the high-energy image (SSH), anti-correlated noise reduction (ACNR), and a general linear noise reduction algorithm (GLNR) are used as conventional DE techniques to separate bone and soft tissue. However, conventional DE techniques cannot accurately decompose the anatomical structures because these techniques are based on the assumptions that X-ray imaging is a linear relationship. This relationship can cause quantum noise as well as anatomical loss of normal tissue and difficulty in detecting lesions. In this study, we propose a non-linear DE technique which requires a step to calculate the coefficient in advance using a calibration phantom. The calibration phantom composed to aluminum and PMMA material to calculate non-linear coefficients using the quadratic fitting model for soft tissue and bone. The results demonstrated that a non-linear DE technique showed the higher contrast-to-noise ratio (CNR), signal to noise ratio (SNR) and figure of merit (FOM) at 60 /70 kVp and 130 kVp. In addition, it showed better performance and image quality than conventional DE technique in terms of material decomposition capability. In conclusion, a non-linear DE technique is expected to increase the diagnostic accuracy in chest radiography.Keywords
This publication has 10 references indexed in Scilit:
- Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtrationMedical Physics, 2009
- Cascaded systems analysis of noise reduction algorithms in dual-energy imagingMedical Physics, 2008
- Optimization of a flat-panel based real time dual-energy system for cardiac imagingMedical Physics, 2006
- Quantitative evaluation of dual-energy digital mammography for calcification imagingPhysics in Medicine & Biology, 2004
- Quantitative evaluation of noise reduction strategies in dual-energy imagingMedical Physics, 2003
- Quantification techniques for dual‐energy cardiac imagingMedical Physics, 1989
- An algorithm for noise suppression in dual energy CT material density imagesIEEE Transactions on Medical Imaging, 1988
- Calcification in pulmonary nodules: detection with dual-energy digital radiography.Radiology, 1986
- Theoretical optimization of dual‐energy x‐ray imaging with application to mammographyMedical Physics, 1985
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976