Ultrasonic particle image velocimetry for improved flow gradient imaging: algorithms, methodology and validation
Authors:
- Ming QianMQMing Qian
- Kun WanKWKun Wan
- Wentao YuWYWentao Yu
- Qiaofeng JinQJQiaofeng Jin
- Tao LingTLTao Ling
- Shen GaoSGShen Gao
- Hairong ZhengHZHairong Zheng
- 19 March 2010
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (7) , 2103-2120
Abstract
This paper presents a new algorithm for ultrasonic particle image velocimetry (Echo PIV) for improving the flow velocity measurement accuracy and efficiency in regions with high velocity gradients. The conventional Echo PIV algorithm has been modified by incorporating a multiple iterative algorithm, sub-pixel method, filter and interpolation method, and spurious vector elimination algorithm. The new algorithms' performance is assessed by analyzing simulated images with known displacements, and ultrasonic B-mode images of in vitro laminar pipe flow, rotational flow and in vivo rat carotid arterial flow. Results of the simulated images show that the new algorithm produces much smaller bias from the known displacements. For laminar flow, the new algorithm results in 1.1% deviation from the analytically derived value, and 8.8% for the conventional algorithm. The vector quality evaluation for the rotational flow imaging shows that the new algorithm produces better velocity vectors. For in vivo rat carotid arterial flow imaging, the results from the new algorithm deviate 6.6% from the Doppler-measured peak velocities averagely compared to 15% of that from the conventional algorithm. The new Echo PIV algorithm is able to effectively improve the measurement accuracy in imaging flow fields with high velocity gradients.Keywords
This publication has 33 references indexed in Scilit:
- Simulation and Validation of Arterial Ultrasound Imaging and Blood FlowUltrasound in Medicine & Biology, 2008
- Atherosclerotic Lesion Size and Vulnerability Are Determined by Patterns of Fluid Shear StressCirculation, 2006
- Acoustic speed and attenuation coefficient in sheep aorta measured at 5-9 MHzUltrasound in Medicine & Biology, 2006
- Seeing WithinCirculation Research, 2004
- Characterizing Vortex Ring Behavior During Ventricular Filling with Doppler Echocardiography: An in Vitro StudyAnnals of Biomedical Engineering, 2004
- A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital PIV image evaluationExperiments in Fluids, 2002
- Association Between Risk Factors for Atherosclerosis and Mechanical Forces in Carotid ArteryStroke, 2000
- A review of the measurement of blood velocity and related quantities using Doppler ultrasoundProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- Repeated filtering in consecutive fractional Fourier domains and its application to signal restorationIEEE Transactions on Signal Processing, 1999