Acoustic non-destructive testing of high temperature degraded concrete with comparison of acoustic impedance
Open Access
- 29 October 2018
- journal article
- research article
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 219, 03003
Abstract
The paper is focused on non-destructive measurement of high temperature degraded concrete test specimens of three mixtures different by the use of coarse aggregate. Testing is done by ultrasonicpulse velocitymethod and Impact-Echo method. Non-destructive results are compared with destructive tests. Ultrasonic pulse velocity, dominant resonance frequency and acoustic impedance are discussed and compared with changes in density, cubic compressive strength, and tensile strength of concrete. The paper suggests possible assessment of degraded concrete by the change in acoustic impedance dependent on residual tensile strength.Keywords
This publication has 5 references indexed in Scilit:
- Post-fire assessment of mechanical properties of concrete with the use of the impact-echo methodConstruction and Building Materials, 2015
- A meso-level investigation into the explosive spalling mechanism of high-performance concrete under fire exposureCement and Concrete Research, 2014
- ErratumSpace and Culture, 2009
- Evaluation of fire-damaged concrete using impact-echo methodMaterials and Structures, 2009
- Influence of elevated temperatures on the mechanical properties of blended cement concretes prepared with limestone and siliceous aggregatesCement and Concrete Composites, 2005