Designing a Long Optical Path Direct-Injection-Integrated Cavity for Laser Absorption Spectroscopy
Open Access
Abstract
Trace gas measurement has a wide range of applications needed in industrial, medical, and environmental protection. With the evolution of time, the demand for real-time, sensitivity, and accuracy of gas detection has been increasingly heightened. Off-axis integrated cavity output spectroscopy (OA-ICOS) is an effective method for the high-sensitivity detection of trace gases. It uses an integrated cavity with two highly reflective mirrors to provide a long optical path, which guarantees its high sensitivity. However, as the reflectivity of the mirrors increases, the intensity of the output light decreases, and the signal-to-noise ratio decreases. This contradiction makes it difficult to achieve a long optical path and a high signal-to-noise ratio together. To combat this issue, this paper proposes a type of integrated cavity using a direct-injection method. This structure, under equivalent mirror conditions, can maintain an effective absorption optical path very close to the original off-axis integrated cavity while increasing the output light intensity hundreds of times. This enhancement increases the sensitivity of OA-ICOS.Keywords
Funding Information
- National Key Research and Development Program of China (2021YFB3901000, 2021YFB3901004)
This publication has 19 references indexed in Scilit:
- Detection of shock-heated hydrogen peroxide (H2O2) by off-axis cavity-enhanced absorption spectroscopy (OA-CEAS)Applied Physics B, 2017
- A widely tunable, near-infrared laser-based trace gas sensor for hydrogen cyanide (HCN) detection in exhaled breathApplied Physics B, 2017
- No influence of CO 2 on stable isotope analyses of soil waters with off‐axis integrated cavity output spectroscopy (OA‐ICOS)Rapid Communications in Mass Spectrometry, 2017
- Studies of cavity enhanced absorption spectroscopy for weak absorption gas measurements2017
- Water vapor δ 2 H, δ 18 O and δ 17 O measurements using an off‐axis integrated cavity output spectrometer – sensitivity to water vapor concentration, delta value and averaging‐timeRapid Communications in Mass Spectrometry, 2016
- High-precision surface-level CO2 and CH4 using off-axis integrated cavity output spectroscopy (OA-ICOS) over Shadnagar, IndiaInternational Journal of Remote Sensing, 2015
- Equilibrator-based measurements of dissolved methane in the surface ocean using an integrated cavity output laser absorption spectrometerActa Oceanologica Sinica, 2015
- Optical re-injection in cavity-enhanced absorption spectroscopyReview of Scientific Instruments, 2014
- Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignmentApplied Optics, 2001
- Integrated cavity output analysis of ultra-weak absorptionChemical Physics Letters, 1998