Comparison of silver-impregnated with standard multi-lumen central venous catheters in critically ill patients*
Authors:
- Pierre KalfonPKPierre Kalfon
- Cyrille de VaumasCVCyrille de Vaumas
- Désiré SambaDSDésiré Samba
- Eric BouletEBEric Boulet
- Jean-Yves LefrantJLJean-Yves Lefrant
- Daniel EyraudDEDaniel Eyraud
- Thierry LhermTLThierry Lherm
- François SantoliFSFrançois Santoli
- Walid NaijaWNWalid Naija
- Bruno RiouBRBruno Riou
- 1 April 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 35 (4) , 1032-1039
Abstract
To evaluate a new silver-impregnated multi-lumen central venous catheter for reducing catheter-related colonization in intensive care patients. Multicenter, prospective, randomized, controlled clinical study. Ten adult intensive care units (multidisciplinary, medical and surgical, university and nonuniversity hospitals) in eight institutions. A total of 577 patients who required 617 multi-lumen central venous catheters between November 2002 and April 2004 were studied. Intensive care adult patients requiring multi-lumen central venous catheters expected to remain in place for ≥3 days were randomly assigned to undergo insertion of silver-impregnated catheters (silver group) or standard catheters (standard group). Catheter colonization was defined as the growth of ≥1,000 colony-forming units in culture of the intravascular tip of the catheter by the vortexing method. Diagnosis of catheter-related infection was performed by an independent and blinded expert committee. A total of 320 catheters were studied in the silver group and 297 in the standard group. Characteristics of the patients, insertion site, duration of catheterization (median, 11 vs. 10 days), and other risk factors for infection were similar in the two groups. Colonization of the catheter occurred in 47 (14.7%) vs. 36 (12.1%) catheters in the silver and the standard groups (p = .35), for an incidence of 11.2 and 9.4 per 1,000 catheter days, respectively. Catheter-related bloodstream infection was recorded in eight (2.5%) vs. eight (2.7%) catheters in the silver and the standard groups (p = .88), for an incidence of 1.9 and 2.1 per 1,000 catheter days, respectively. The use of silver-impregnated multi-lumen catheters in adult intensive care patients is not associated with a lower rate of colonization than the use of standard multi-lumen catheters.Keywords
This publication has 55 references indexed in Scilit:
- Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patientsDiagnostic Microbiology and Infectious Disease, 2000
- Prevention of Intravascular Catheter–Related InfectionsAnnals of Internal Medicine, 2000
- Antiseptic‐bonded central venous catheters and bacterial colonisationAnaesthesia, 1999
- Decreasing Catheter Colonization Through the Use of an Antiseptic-Impregnated CatheterChest, 1999
- Intravascular-catheter-related infectionsThe Lancet, 1998
- Influence of Triple-Lumen Central Venous Catheters Coated With Chlorhexidine and Silver Sulfadiazine on the Incidence of Catheter-Related BacteremiaArchives of internal medicine (1960), 1998
- A Prospective Randomized Trial of an Antibiotic-and Antiseptic-Coated Central Venous Catheter in the Prevention of Catheter-Related InfectionsArchives of Surgery, 1997
- Evaluation of chlorhexidine and silver-sulfadiazine impregnated central venous catheters for the prevention of bloodstream infection in leukaemic patients: a randomized controlled trialJournal of Hospital Infection, 1997
- Antiseptic-impregnated central venous catheters reduce the incidence of bacterial colonization and associated infection in immunocompromised transplant patientsEuropean Journal of Anaesthesiology, 1997
- Nosocomial Bloodstream Infection in Critically III PatientsJAMA, 1994