Two Potential Causes of EPL Rupture after Distal Radius Volar Plate Fixation
Authors:
- Alex DeCarvalhoADAlex DeCarvalho
- Elizabeth A MikolaEMElizabeth A Mikola
- John M VeitchJVJohn M Veitch
- Moheb S MoneimMMMoheb S Moneim
- 1 October 2006
- journal article
- case report
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 451, 218-222
Abstract
Rupture of the extensor pollicis longus tendon can occur after volar plate fixation of dorsally comminuted distal radius fractures. We attempted to identify the etiology of extensor pollicis longus tendon injury after volar plate fixation of the distal radius and potential solutions to this problem. After describing two case reports, we examine six cadaveric specimens and retrospectively review 10 selected patients to evaluate possible technique refinements to minimize damage to the extensor pollicis longus tendon during volar plating of the distal radius. We identify specific screw holes in three commercially available volar distal radius plates that direct the drill bit or prominent screw tips into the third extensor compartment. In addition, after reduction and plate fixation, bone fragments or dorsal gapping may predispose the extensor pollicis longus tendon to injury. We recommend either using shorter screw lengths or leaving the implicated plate holes unfilled. In addition, we suggest consideration of an open assessment of the third extensor compartment, if indicated, as performed through a small dorsal incision ulnar to Lister's tubercle.Keywords
This publication has 14 references indexed in Scilit:
- Rupture of the extensor pollicis longus tendon: a study of aetiological factorsScandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 2004
- Fixation of Distal Radius Fractures Using AO Titanium Volar Distal Radius PlateHand Surgery, 2003
- Osteosynthesis of distal radial fractures with a volar locking screw plate systemInternational Orthopaedics, 2003
- Einengung des dritten Strecksehnenfaches bei gering dislozierter distaler Radiusfraktur mit Gefahr einer Extensor pollicis longus-SehnenrupturHandchirurgie · Mikrochirurgie · Plastische Chirurgie, 2002
- THE TREATMENT OF UNSTABLE DISTAL RADIUS FRACTURES WITH VOLAR FIXATIONHand Surgery, 2000
- Delayed rupture of the thumb extensor tendon:A 5-year study of 18 consecutive casesActa Orthopaedica, 1994
- Extensor pollicis longus rupture at the tip of a prominent fixation screw: Report of three casesThe Journal of Hand Surgery, 1993
- Late rupture of the extensor pollicis longus tendon: The case against attritionJournal of Hand Surgery (European Volume), 1988
- Rupture of the Extensor Pollicis Longus Tendon in Undisplaced Colles’ Type of FractureHand, 1982
- Rupture of the Extensor Pollicis Longus Tendon after Fracture of the Lower End of the Radius — a Clinical and Microangiography StudyHand, 1979