Stress Correction for Removal of Material in X-Ray Stress Determination
Authors:
- 1 May 1994
- journal article
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 22 (3) , 217-221
Abstract
To determine residual stresses in a (flat) plate or bar with a rectangular cross-section by X-ray diffraction after removal of material, we can sectionally approximate the measured stress curve with depth using power series, then consequently evaluate the additional stresses created by removal, and finally obtain the true stress distribution with depth before the layers were removed. Formulas to evaluate corrections for stress have been derived. Two examples demonstrate that power series with few terms can provide us with an approximation good enough for the measured stress curve, and that the influence of the approximation on the corrective result is far less than that of the errors arising from the X-ray stress determination itself.Keywords
This publication has 2 references indexed in Scilit:
- X-Ray Measurements of Residual Stress in the Whole Cross Section of a PlateTransactions of the Japan Society of Mechanical Engineers, 1970
- Mathematical Correction for Stress in Removed Layers in X-Ray Diffraction Residual Stress AnalysisSAE International Journal of Advances and Current Practices in Mobility, 1958