Can Thromboelastography performed on kaolin‐activated citrated samples from critically ill patients provide stable and consistent parameters?
- 22 February 2010
- journal article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 32 (2) , 167-173
Abstract
Thromboelastography (TEGis a potentially useful tool but analysis within 4-6 min of collection imposes limitations on its use and access. The use of citrate blood tubes potentially increases the time frame for processing specimens. There is, however, limited research on the stability of citrate specimens, timing of processing and the accuracy of TEGesults. The purpose of this study was to examine the effects of early and delayed processing on TEGarameters using kaolin-activated citrated blood samples in the intensive care population. TEGnalysis was performed on 61 patients. Blood was collected into two 3.2% sodium citrate (0.105 m) tubes. Kaolin-activated samples were analysed at 15, 30 and 120 min postcollection. TEGarameters analysed included reaction time (R), clot formation time (K), alpha angle (a), maximum amplitude, LY30, the coagulation index, time to maximum rate of thrombus generation, maximum rate of thrombus generation and total thrombus generation. Sixty-one critically ill patients were included. The results of the anova showed that time from collection was significantly associated with the TEGesults (P < 0.05). On comparison of individual outcome variables, this difference in most cases was due to changes over time from 30 to 120 min. Furthermore, progressive changes in TEGarameters such as decreasing R were suggestive of a trend toward hypercoagulability of the specimens. Processing of kaolin-activated citrate TEGpecimens can begin as early as 15 min postvenipuncture. However, delaying processing by more than 30 min leads to a significant change in results.Griffith Health, School of MedicineNo Full TexKeywords
This publication has 19 references indexed in Scilit:
- The value of rotation thromboelastometry to monitor disturbed perioperative haemostasis and bleeding risk in patients with cardiopulmonary bypassBlood Coagulation & Fibrinolysis, 2008
- Simple coagulation tests improve survival prediction in patients with septic shockJournal of Thrombosis and Haemostasis, 2008
- Transfusion Triggers in Orthotopic Liver Transplantation: A Comparison of the Thromboelastometry Analyzer, the Thromboelastogram, and Conventional Coagulation TestsJournal of Cardiothoracic and Vascular Anesthesia, 2006
- Central laboratory and point of care assessment of perioperative hemostasisCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- Thrombelastography/thromboelastometryClinical and Laboratory Haematology, 2005
- Thromboelastography with citrated bloodBlood Coagulation & Fibrinolysis, 2004
- Thromboelastography: a reliable test?Blood Coagulation & Fibrinolysis, 2001
- Citrate Storage Affects Thrombelastograph®AnalysisAnesthesiology, 2000
- Changes in transfusion therapy and reexploration rate after institution of a blood management program in cardiac surgical patientsJournal of Cardiothoracic and Vascular Anesthesia, 1995
- THROMBELASTOGRAPHYBritish Journal of Anaesthesia, 1992