Arterial Stiffness Using Radial Arterial Waveforms Measured at the Wrist as an Indicator of Diabetic Control in the Elderly
- 4 October 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (2) , 243-252
Abstract
Although current technique of photoplethysmography (PPG) is a popular noninvasive method of waveform contour analysis in assessing arterial stiffness, data obtained are frequently affected by various environmental and physiological factors. We proposed an easily operable air pressure sensing system (APSS) for radial arterial signal capturing. Totally, 108 subjects (young, the aged with or without diabetes) were recruited from July 2009 to May 2010. Arterial waveform signals from the wrist were obtained and analyzed using Hilbert-Huang transformation (HHT). Through ensemble empirical mode decomposition (EEMD), the signals were decomposed into eight intrinsic mode functions (IMF1-8) of which IMF5 was found to be the desired signal with a discernible diastolic peak. The results showed significant differences in reflection index (RI) and stiffness index (SI) from the young subjects and those from the aged participants with or without diabetes. Significant differences in RI and SI were also noted between subjects with well-controlled diabetes and those without. Good reproducibility and correlation were demonstrated. In conclusion, the present study proposed the application of radial arterial signal capturing subsystem and HHT in acquiring more reliable data on RI and SI compared with the conventional PPG method.Keywords
This publication has 26 references indexed in Scilit:
- Novel application of parameters in waveform contour analysis for assessing arterial stiffness in aged and atherosclerotic subjectsAtherosclerosis, 2010
- Measuring Pulse Wave Velocity Using ECG and PhotoplethysmographyJournal of Medical Systems, 2010
- Assessment of Endothelial Function Using Arterial Pressure SignalsJournal of Signal Processing Systems, 2009
- Adaptive threshold method for the peak detection of photoplethysmographic waveformComputers in Biology and Medicine, 2009
- Nonlinear phase interaction between nonstationary signals: A comparison study of methods based on Hilbert-Huang and Fourier transformsPhysical Review E, 2009
- Nonlinear Pressure-Flow Relationship Is Able to Detect Asymmetry of Brain Blood Circulation Associated with Midline ShiftJournal of Neurotrauma, 2009
- A Novel Noninvasive Measurement Technique for Analyzing the Pressure Pulse Waveform of the Radial ArteryIEEE Transactions on Biomedical Engineering, 2007
- Respiration-induced changes in tissue blood volume distal to occluded artery, measured by photoplethysmographyJournal of Biomedical Optics, 2006
- A confidence limit for the empirical mode decomposition and Hilbert spectral analysisProceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2003
- A NEW VIEW OF NONLINEAR WATER WAVES: The Hilbert SpectrumAnnual Review of Fluid Mechanics, 1999