Computational simulation of the flow dynamic field in a porous ureteric stent
Authors:
Open Access
- 28 June 2022
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (8) , 2373-2387
Abstract
Ureteric stents are employed clinically to manage urinary obstructions or other pathological conditions. Stents made of porous and biodegradable materials have gained increasing interest, because of their excellent biocompatibility and the potential for overcoming the so-called ‘forgotten stent syndrome’. However, there is very limited characterisation of their flow dynamic performance. In this study, a CFD model of the occluded and unoccluded urinary tract was developed to investigate the urinary flow dynamics in the presence of a porous ureteric stent. With increasing the permeability of the porous material (i.e., from 10−18 to 10−10 m2) both the total mass flow rate through the ureter and the average fluid velocity within the stent increased. In the unoccluded ureter, the total mass flow rate increased of 7.7% when a porous stent with permeability of 10−10 m2 was employed instead of an unporous stent. Drainage performance further improved in the presence of a ureteral occlusion, with the porous stent resulting in 10.2% greater mass flow rate compared to the unporous stent. Findings from this study provide fundamental insights into the flow performance of porous ureteric stents, with potential utility in the development pipeline of these medical devices. Graphical abstractKeywords
This publication has 67 references indexed in Scilit:
- Comparison of a biodegradable ureteral stent versus the traditional double-J stent for the treatment of ureteral injury: an experimental studyBiomedical Materials, 2012
- Tetrahedral vs. polyhedral mesh size evaluation on flow velocity and wall shear stress for cerebral hemodynamic simulationComputer Methods in Biomechanics and Biomedical Engineering, 2011
- Multi‐Featured Macroporous Agarose–Alginate Cryogel: Synthesis and Characterization for Bioengineering ApplicationsMacromolecular Bioscience, 2010
- Fabrication of three-dimensional porous cell-laden hydrogel for tissue engineeringBiofabrication, 2010
- Ureteral stents: new ideas, new designsTherapeutic Advances in Urology, 2010
- The ‘buoy’ stent: evaluation of a prototype indwelling ureteric stent in a porcine modelBJU International, 2009
- Design and validation of a dynamic flow model simulating encrustation of biomaterials in the urinary tractJournal of Pharmacy and Pharmacology, 2003
- Permeability and diffusivity for water transport through hydrogel membranesJournal of Membrane Science, 2003
- Clinical Effectiveness of New Stent Design: Randomized Single-Blind Comparison of Tail and Double-Pigtail StentsJournal of Endourology, 2000
- Characterization of biofilm and encrustation on ureteric stents in vivoBritish Journal of Urology, 1994