Safety and Glycemic Outcomes During the MiniMed TM Advanced Hybrid Closed-Loop System Pivotal Trial in Children and Adolescents with Type 1 Diabetes
Authors:
- Catherine PihokerCPCatherine Pihoker
- Dorothy I. ShulmanDSDorothy I. Shulman
- Gregory P. ForlenzaGFGregory P. Forlenza
- Kevin B. KaisermanKKKevin B. Kaiserman
- Jennifer L. SherrJSJennifer L. Sherr
- James R. ThrasherJTJames R. Thrasher
- Bruce A. BuckinghamBBBruce A. Buckingham
- Mark S. KipnesMKMark S. Kipnes
- Bruce W. BodeBBBruce W. Bode
- Anders L. CarlsonACAnders L. Carlson
- Scott W. LeeSLScott W. Lee
Open Access
- 7 November 2023
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (11) , 755-764
Abstract
Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population ( N = 160, aged 7–17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t -test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% ( N = 160) to 7.4 ± 0.7% ( N = 136) ( P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study ( P < 0.001), without change in CV, time spent below range (TBR) N = 52), an AIT of 2 h ( N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR 180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.Keywords
This publication has 36 references indexed in Scilit:
- Estimating the total incidence of type 1 diabetes in children and adolescents aged 0–19 years from 1990 to 2050: a global simulation-based analysisThe Lancet Diabetes & Endocrinology, 2022
- In Silico Evaluation of the Medtronic 780G System While Using the GS3 and Its Calibration-Free Successor, the G4S SensorAnnals of Biomedical Engineering, 2022
- Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trialThe Lancet Digital Health, 2022
- Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop TrialDiabetes Technology & Therapeutics, 2021
- Racial–Ethnic Disparities in Diabetes Technology use Among Young Adults with Type 1 DiabetesDiabetes Technology & Therapeutics, 2021
- A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trialThe Lancet, 2021
- A Randomized Trial of Closed-Loop Control in Children with Type 1 DiabetesNew England Journal of Medicine, 2020
- State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018Diabetes Technology & Therapeutics, 2019
- Co-occurrence of early diabetes-related complications in adolescents and young adults with type 1 diabetes: an observational cohort studyThe Lancet Child & Adolescent Health, 2019
- Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 DiabetesDiabetes Technology & Therapeutics, 2017