Spark Chamber Pulsing System
Authors:
- 1 November 1964
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 35 (11) , 1567-1571
Abstract
A spark chamber pulser is described in which several avalanche transistors and a step‐up transformer drive directly an air spark gap whose trigger electrode is surrounded by barium titanate dielectric. Output pulses of from 1 to 25 kV with a risetime of 1 nsec and an output impedance of less than 1 Ω can be obtained. The total delay from the 1‐V input pulse to the high voltage output pulse ranges from 17 to 65 nsec depending on the desired voltage and the mode of operation of the spark gap. Jitter times are less than 3 nsec. When Elkonite‐tipped electrodes are used, the gap life is in excess of 5 000 000 pulses. Methods are given for reducing the delay to less than 25 nsec at 20 kV and the recovery time to less than 200 μsec at 10 kV.Keywords
This publication has 9 references indexed in Scilit:
- Modular spark chambersNuclear Instruments and Methods, 1963
- Reduction of Delay between Particle Passage and Spark Chamber SparkIRE Transactions on Nuclear Science, 1962
- Avalanche Transistor CircuitsReview of Scientific Instruments, 1961
- On the Use of 2N504 Transistors in the Avalanche Mode for Nuclear InstrumentationReview of Scientific Instruments, 1960
- Physical Principles of Avalanche Transistor Pulse CircuitsProceedings of the IRE, 1959
- Ionization Rates for Electrons and Holes in SiliconPhysical Review B, 1958
- CorrespondenceProceedings of the IRE, 1958
- Alloyed Junction Avalanche TransistorsBell System Technical Journal, 1955
- Avalanche Breakdown in GermaniumPhysical Review B, 1955