Effect of a pocket compression device on hematomas, skin reactions, and comfort in patients receiving a cardiovascular implantable electronic device: a randomized controlled trial
- 6 March 2021
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 63 (2) , 275-281
Abstract
Aim/objective Aim to evaluate the safety and effectiveness of a pocket compression device in patients undergoing cardiovascular implantable electronic device (CIED) implantation. Material and methods This randomized controlled trial included 54 patients in the control group (elastic adhesive tape) and 54 patients in the experimental group (pocket compression device). A sandbag was positioned over the pocket after CIED implantation, using elastic adhesive tape in the control group and a novel pocket compression device in the experimental group. The primary outcome was the incidence of pocket hematomas, and the secondary outcomes were adverse skin reactions, the need for sandbag positional adjustments, and patient comfort. Results The distributions of age, sex, and clinical and procedure characteristics was not significantly different between the two groups (P>0.05). The occurrence of hematomas was lower when using the pocket compression device than in the control group (13.0% vs. 44.4%, Pvs. 31.5%, 0% vs. 11.1% respectively, [all PP<0.001). Conclusion A pocket compression device can significantly decrease the incidence of pocket hematomas, adverse skin reactions, and positional adjustments when patients are undergoing CIED, which can improve patient comfort and decrease the nursing workload. ClinicalTrials.gov NCT04389398Keywords
Funding Information
- Fund of the First Affiliated Hospital of Xi'an Jiaotong University (2019HL-08)
This publication has 21 references indexed in Scilit:
- Pocket Hematoma: A Call for DefinitionPacing and Clinical Electrophysiology, 2015
- The safety and efficacy of antithrombotic therapy in patients undergoing cardiac rhythm device implantation: a meta-analysisEP Europace, 2015
- Novel Compression Tool to Prevent Hematomas and Skin Erosions After Device ImplantationCirculation Journal, 2015
- Newer Hemostatic Agents Used in the Practice of Dermatologic SurgeryDermatology Research and Practice, 2013
- 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapyEuropean Heart Journal, 2013
- Pacemaker or Defibrillator Surgery without Interruption of AnticoagulationNew England Journal of Medicine, 2013
- 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalitiesThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Is the routine pressure dressing after thyroidectomy necessary? A prospective randomized controlled studyBMC Ear, Nose and Throat Disorders, 2008
- The Frequency and Incremental Cost of Major Complications Among Medicare Beneficiaries Receiving Implantable Cardioverter-DefibrillatorsJACC, 2006