Optical spectrometers play a key role in acquiring rich photonic information in both scientific research and a wide variety of applications. In this work, we present a new spectrometer with an ultrahigh resolution of better than 0.012 nm/pixel in the 170–600 nm spectral region using a grating-integrated module that consists of 19 subgratings without any moving parts. By using two-dimensional (2D) backsideilluminated complementary metal-oxide-semiconductor (BSI-CMOS) array detector technology with 2048 × 2048 pixels, a high data acquisition speed of approximately 25 spectra per second is achieved. The physical photon-sensing size of the detector along the one-dimensional wavelength direction is enhanced by a factor of 19 to approximately 428 mm, or 38912 pixels, to satisfy the requirement of seamless connection between two neighboring subspectral regions without any missing wavelengths throughout the entire spectral region. As tested with a mercury lamp, the system has advanced performance capabilities characterized by the highest k parameter reported to date, being approximately 3.58 × 104, where k = (working wavelength region)/(pixel resolution). Data calibration and analysis as well as a method of reducing background noise more efficiently are also discussed. The results presented in this work will stimulate further research on precision spectrometers based on advanced BSI-CMOS array detectors in the future.Keywords
Funding Information
- National Natural Science Foundation of China (61427815, 61274054)
This publication has 20 references indexed in Scilit:
- Miniature, sub-nanometer resolution Talbot spectrometerOptics Letters, 2016
- Optical fiber smartphone spectrometerOptics Letters, 2016
- Core/shell-structured upconversion nanophosphor and cadmium-free quantum-dot bilayer-based near-infrared photodetectorsOptics Letters, 2015
- Hybrid plasmon photonic crystal resonance grating for integrated spectrometer biosensorOptics Letters, 2015
- Aberration analysis of a concentric imaging spectrometer with a convex gratingOptics Communications, 2014
- Combination of a spectrometer-on-chip and an array of Young’s interferometers for laser spectrum monitoringOptics Letters, 2014
- Relative and absolute intensity calibrations of a modern broadband echelle spectrometerMeasurement Science and Technology, 2007
- Solid-State Array Detectors for Analytical SpectrometryApplied Spectroscopy, 1997
- Calibration of Instruments Measuring Reflectance and TransmittanceApplied Optics, 1972
- Interference Measurements in the Spectra of Neon and Natural MercuryJournal of the Optical Society of America, 1950